ExamGecko
Home / DELL / D-PEXE-IN-A-00
Ask Question

D-PEXE-IN-A-00: Dell PowerEdge XE9680 and XE8640 Install

Vendor:
Exam Questions:
14
 Learners
  2.370
Last Updated
February - 2025
Language
English
1 Quizzes
PDF | VPLUS

The D-PEXE-IN-A-00 also known as Dell EMC PowerEdge XE9680 and XE8640 Install, this exam is crucial for professionals in the field of Dell EMC PowerEdge installation. To increase your chances of passing, practicing with real exam questions shared by those who have succeeded can be invaluable. In this guide, we’ll provide you with practice test questions and answers, offering insights directly from candidates who have already passed the exam.

Why Use D-PEXE-IN-A-00 Practice Test?

  • Real Exam Experience: Our practice tests accurately replicate the format and difficulty of the actual D-PEXE-IN-A-00 exam, providing you with a realistic preparation experience.

  • Identify Knowledge Gaps: Practicing with these tests helps you identify areas where you need more study, allowing you to focus your efforts effectively.

  • Boost Confidence: Regular practice with exam-like questions builds your confidence and reduces test anxiety.

  • Track Your Progress: Monitor your performance over time to see your improvement and adjust your study plan accordingly.

Key Features of D-PEXE-IN-A-00 Practice Test:

  • Up-to-Date Content: Our community ensures that the questions are regularly updated to reflect the latest exam objectives and technology trends.

  • Detailed Explanations: Each question comes with detailed explanations, helping you understand the correct answers and learn from any mistakes.

  • Comprehensive Coverage: The practice tests cover all key topics of the D-PEXE-IN-A-00 exam, including:

    • PowerEdge XE9680 and XE8640 Hardware Components
    • Installation Procedures
    • Power Distribution Units (PDUs)
    • Server Rack Compatibility
    • Network Connectivity
  • Customizable Practice: Create your own practice sessions based on specific topics or difficulty levels to tailor your study experience to your needs.

Exam Details:

  • Exam Number: D-PEXE-IN-A-00

  • Exam Name: Dell EMC PowerEdge XE9680 and XE8640 Install

  • Length of Test: 90 minutes

  • Exam Format: Web-based with multiple-choice, multiple-response, drag-and-drop, and point-and-click questions

  • Exam Language: English

  • Number of Questions: 50 questions

  • Passing Score: 70%

Use the member-shared D-PEXE-IN-A-00 Practice Tests to ensure you're fully prepared for your certification exam. Start practicing today and take a significant step towards achieving your certification goals!

DELL D-PEXE-IN-A-00 Practice Tests

Related questions

A deployment engineer is installing a PowerEdge XE8640 server. The server is on a lift, and they have aligned the server inner rails with the rail assemble that are secured in the rack. The engineer can only push the server into the rack a short distance before it stops. Pushing forcefully causes the rack to slide back.

What action should the deployment engineer take?

Become a Premium Member for full access
  Unlock Premium Member

A deployment engineer is connecting the network cables on an XE9680 server. The data center administrator wants to know why the server does not have an OCP card for network connectivity.

How should the engineer respond to the administrator's query?

Become a Premium Member for full access
  Unlock Premium Member

A deployment engineer is installing eight PowerEdge XE9680 servers. Two servers will be installed in each of four racks. The data center managers must plan for the power needed to supply power to the four racks.

What power consumption information can the deployment engineer give the data center manager?

Become a Premium Member for full access
  Unlock Premium Member

A deployment engineer installed and powered on a XE8640 server. The Linux operating system is installed. They need to update the drivers on the server.

What is a consideration before updating the driver?

A single graphics driver supports all modern GPUs.
A single graphics driver supports all modern GPUs.
Each GPU model has a distinct driver package.
Each GPU model has a distinct driver package.
The driver package only supports Windows operating systems.
The driver package only supports Windows operating systems.
You can upload the driver package using the iDRAC UI.
You can upload the driver package using the iDRAC UI.
Suggested answer: B
Explanation:

Understanding GPU Drivers:

Graphics Processing Units (GPUs) require specific drivers to ensure optimal performance and compatibility with the operating system. Each GPU model typically has a unique driver package designed to leverage its capabilities and architecture.

Driver Packages for Different GPU Models:

For the Dell PowerEdge XE8640, which may be equipped with multiple GPU models, it is crucial to identify the exact GPU models installed in the server. Each GPU model, whether it's from NVIDIA, AMD, or another manufacturer, will have a distinct driver package.

Importance of Model-Specific Drivers:

Using the correct driver for each GPU model ensures that the GPU operates efficiently, provides the intended performance, and remains stable under various workloads. Incorrect drivers can lead to suboptimal performance, compatibility issues, or system instability.

Steps to Update Drivers on Linux:

Identify the GPU models installed in the server. This can be done using commands like lspci | grep -i vga or similar tools that list the hardware components.

Visit the GPU manufacturer's website (e.g., NVIDIA, AMD) to download the appropriate drivers for each GPU model.

Follow the manufacturer's installation instructions, which typically involve downloading the driver package, extracting it, and running an installation script or using package management tools.

Using iDRAC for Driver Updates:

While the iDRAC (Integrated Dell Remote Access Controller) UI can be used for various management tasks, uploading driver packages directly via iDRAC is not typically supported. Drivers are usually installed within the operating system environment.

Compatibility with Linux:

Ensure that the driver package is compatible with the Linux distribution and kernel version installed on the XE8640. GPU manufacturers often provide detailed compatibility information and installation guides specific to various Linux distributions.

Reference to Official Documentation:

Dell's support site and the GPU manufacturer's documentation provide comprehensive guides on downloading and installing the correct drivers for various operating systems, including Linux.

Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on hardware configurations and driver installations.

NVIDIA/AMD Official Documentation: These resources offer specific instructions on downloading and installing GPU drivers for different operating systems and GPU models.

asked 16/09/2024
CHARLES ADAMA
34 questions

A deployment engineer is installing an XE9680 server. The network connectivity has 24 optical cables that route to switches in the data center. The administrator questions the use of a cable management arm (CMA).

What are two items to consider when installing a CMA?

The CMA can be installed to open on either the left or right side of the server.
The CMA can be installed to open on either the left or right side of the server.
Do not route optical cables through the CMA.
Do not route optical cables through the CMA.
A CMA can only be installed with a strain relief bar.
A CMA can only be installed with a strain relief bar.
The XE9680 does not support a CMA.
The XE9680 does not support a CMA.
Suggested answer: A, B
Explanation:

When installing a Cable Management Arm (CMA) on the Dell PowerEdge XE9680 server, there are specific considerations to ensure proper installation and operation:

CMA Orientation:

Installation Flexibility: The CMA for the XE9680 can be installed to open on either the left or right side of the server. This flexibility allows for better management of space within the rack and ensures that the CMA can accommodate the specific layout of your data center (Dell) (Dell).

Cable Routing:

Avoid Routing Optical Cables Through the CMA: Optical cables are typically more sensitive and less flexible compared to other types of cables. Routing them through the CMA can lead to bending, twisting, or other stresses that may damage the cables and affect network performance. Therefore, it is advised not to route optical cables through the CMA (Dell) (Dell).

Installation Process:

Align and Install the CMA: Attach the CMA to the designated mounting points on the server rails. Ensure that it is securely fastened and aligned properly to avoid any issues when extending or retracting the server from the rack.

Organize Cables: Use the provided cable management features to route and secure other cables, ensuring they are not pinched or overly stressed. Avoid including optical cables in the CMA to prevent potential damage.

Post-Installation Checks:

Verify Movement: Ensure that the server can be smoothly extended and retracted with the CMA in place without any cables getting caught or strained.

Secure Connections: Double-check all cable connections to ensure they are secure and functioning correctly.

These steps are crucial for maintaining the integrity and performance of the server and the connected network infrastructure. Proper cable management not only ensures safety but also enhances the reliability and maintainability of the data center setup.

Dell PowerEdge XE9680 Installation and Service Manual (Dell).

Dell XE9680 Rack Rail with Cable Management Arm Information (Dell) (Dell).

asked 16/09/2024
Borat Kajratov
49 questions

What must be considered regarding stab-in rails with installing a PowerEdge XE server?

Enable a vertical installation of the server with the use of J-slots.
Enable a vertical installation of the server with the use of J-slots.
Do not support extending the server from the rack.
Do not support extending the server from the rack.
Only used in 4-post, square hole racks.
Only used in 4-post, square hole racks.
Inner rail must be installed on the server before installing in rack.
Inner rail must be installed on the server before installing in rack.
Suggested answer: C
Explanation:

Understanding Stab-in Rails:

Stab-in rails are designed to simplify the server installation process. These rails enable a quick and straightforward installation of the server into the rack.

Compatibility and Usage:

Stab-in rails are specifically designed for use in 4-post racks with square holes. This compatibility ensures stability and proper fitting within the rack structure.

Installation Process:

Before initiating the installation, verify that the rack is a 4-post, square hole type.

Position the stab-in rails to align with the square holes on the rack. Typically, stab-in rails have tabs that fit precisely into these square holes.

Mounting the Server:

Once the rails are securely attached to the rack, the server can be mounted. The design of the stab-in rails facilitates a smooth insertion of the server, ensuring it is securely held in place.

Ensuring Proper Fit:

After the server is mounted, check to ensure that it is level and securely attached. This step is crucial to prevent any movement or displacement that could occur due to vibrations or physical disturbances.

Dell EMC PowerEdge XE9680 and XE8640 Installation and Service Manual: This manual provides detailed instructions on the use and installation of stab-in rails, including compatibility with specific rack types.

Dell EMC Technical Specifications Guide: Offers comprehensive specifications and compatibility information for different mounting and installation hardware used with Dell PowerEdge servers.

asked 16/09/2024
james james
33 questions

A deployment engineer arrives on-site to install an XE9680 server. The server lift does not have the ability to maneuver beneath the XE9680 shipping pallet.

How many people must you have to physically pick up the server to place it on the lift shelf?

4. The server is heavy, and the lift shelf does not rest on the floor.
4. The server is heavy, and the lift shelf does not rest on the floor.
3. Two people are needed to tilt the server while the third person slides the shelf beneath the server.
3. Two people are needed to tilt the server while the third person slides the shelf beneath the server.
2. At least one person on each side is needed to pick up the server and place on the lift.
2. At least one person on each side is needed to pick up the server and place on the lift.
1. They can tilt the server and slide the lift underneath.
1. They can tilt the server and slide the lift underneath.
Suggested answer: A
Explanation:

Weight and Size of the PowerEdge XE9680:

The Dell PowerEdge XE9680 server is designed for high performance, which often results in a larger and heavier form factor. Handling such servers typically requires multiple people to ensure safety and prevent damage.

Ergonomic Considerations:

Due to its weight and size, it is crucial to follow proper ergonomic practices when lifting and moving the server. This minimizes the risk of injury and ensures the server is handled safely.

Number of People Required:

For the XE9680, it is recommended to have four people when physically picking up the server to place it on the lift shelf. This recommendation is based on the server's weight and the need to maneuver it safely onto the lift.

Safety and Coordination:

Each person should position themselves on one side of the server, ensuring an even distribution of weight. This coordinated effort helps in lifting the server evenly and reducing the risk of dropping or mishandling it.

Procedure for Lifting:

Two individuals should position themselves at the front corners, and two at the rear corners of the server. On a coordinated count, all four should lift the server together and place it gently onto the lift shelf.

The lift shelf should be stable and able to support the weight of the server once it is placed on it.

Using the Lift:

Once the server is on the lift shelf, it can be maneuvered into the desired position in the rack. Ensure that the lift is rated for the weight of the XE9680 to avoid any mechanical failures.

Reference to Official Documentation:

Dell's installation guides and service manuals typically provide guidelines on the number of personnel required for handling large and heavy servers, ensuring both safety and compliance with best practices.

Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed guidelines on handling and installing the XE9680 server, including the recommended number of personnel required for safe handling.

Dell EMC Technical Specifications Guide: Offers insights into the physical dimensions and weight of the PowerEdge XE9680, informing the need for multiple personnel for safe handling and installation.

asked 16/09/2024
Prashant Bari
46 questions

A customer wants to implement 20 PowerEdge XE9680 servers for development and rendering of their studio CGI production. The solution includes a shared development environment with multiple outside partners, professionals, and hobbyists.

Due to the heating and cooling limitations of the data center, what GPUs should be used for the servers?

Intel Data Center Max 1550
Intel Data Center Max 1550
NVIDIA A100 GPUs
NVIDIA A100 GPUs
AMD ROCm
AMD ROCm
NVIDIA H100 GPUs
NVIDIA H100 GPUs
Suggested answer: B
Explanation:

For a customer implementing PowerEdge XE9680 servers in a data center with heating and cooling limitations, the NVIDIA A100 GPUs are a suitable choice. Here's a detailed explanation:

GPU Efficiency: The NVIDIA A100 GPUs are known for their energy efficiency, which is crucial in environments with heating and cooling constraints1.

Performance: These GPUs provide excellent performance for CGI production, supporting complex rendering tasks1.

Compatibility: The PowerEdge XE9680 supports a range of powerful GPUs, including the NVIDIA A100, which is designed for AI, machine learning, and high-performance computing tasks1.

Cooling Requirements: The NVIDIA A100 GPUs have a lower thermal design power (TDP) compared to the NVIDIA H100 GPUs, making them more suitable for data centers with limited cooling capabilities1.

By choosing NVIDIA A100 GPUs, the customer can ensure that their PowerEdge XE9680 servers will deliver the required performance for CGI production while adhering to the data center's heating and cooling limitations.

asked 16/09/2024
Hany Mohammed
35 questions

A deployment engineer is discussing the benefits of the PowerEdge XE9680 to a data center manager. A customer has many PowerEdge servers. They require the greatest amount of network throughput possible. The manager asks how many PCle risers and network PCI cards the server can support.

What should be the response?

Become a Premium Member for full access
  Unlock Premium Member

A deployment engineer is installing a PowerEdge XE8640 server in a rack with round holes. They cannot get the outer rail portion to fit flush with the rack frame.

What is the reason the outer rail is not flush with the frame?

Become a Premium Member for full access
  Unlock Premium Member