ExamGecko
Home Home / VMware / 5V0-21.21

5V0-21.21: VMware HCI Master Specialist

VMware HCI Master Specialist
Vendor:

VMware

VMware HCI Master Specialist Exam Questions: 66
VMware HCI Master Specialist   2.370 Learners
Take Practice Tests
Comming soon
PDF | VPLUS

The 5V0-21.21 exam, also known as VMware HCI Master Specialist, is a crucial certification for professionals in the field of hyper-converged infrastructure (HCI). To increase your chances of passing, practicing with real exam questions shared by those who have succeeded can be invaluable. In this guide, we’ll provide you with practice test questions and answers, offering insights directly from candidates who have already passed the exam.

Why Use 5V0-21.21 Practice Test?

  • Real Exam Experience: Our practice tests accurately replicate the format and difficulty of the actual 5V0-21.21 exam, providing you with a realistic preparation experience.

  • Identify Knowledge Gaps: Practicing with these tests helps you identify areas where you need more study, allowing you to focus your efforts effectively.

  • Boost Confidence: Regular practice with exam-like questions builds your confidence and reduces test anxiety.

  • Track Your Progress: Monitor your performance over time to see your improvement and adjust your study plan accordingly.

Key Features of 5V0-21.21 Practice Test:

  • Up-to-Date Content: Our community ensures that the questions are regularly updated to reflect the latest exam objectives and technology trends.

  • Detailed Explanations: Each question comes with detailed explanations, helping you understand the correct answers and learn from any mistakes.

  • Comprehensive Coverage: The practice tests cover all key topics of the 5V0-21.21 exam, including hyper-converged infrastructure, VMware vSAN technologies, and cloud solutions.

  • Customizable Practice: Create your own practice sessions based on specific topics or difficulty levels to tailor your study experience to your needs.

Exam Details:

  • Exam Number: 5V0-21.21

  • Exam Name: VMware HCI Master Specialist

  • Length of Test: 2 hours (120 minutes)

  • Exam Format: Multiple-choice, multiple-selection multiple-choice, drag-and-drop, matching

  • Exam Language: English

  • Number of Questions: 60 questions

  • Passing Score: 300 out of 500 (60%)

Use the member-shared 5V0-21.21 Practice Tests to ensure you're fully prepared for your certification exam. Start practicing today and take a significant step towards achieving your certification goals!

Related questions

An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the ''Full-data migration'' option.

What will happen after this action is taken?

A.
The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.
A.
The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.
Answers
B.
The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.
B.
The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.
Answers
C.
The host will enter in maintenance mode and only data with no redundancy will remain accessible.
C.
The host will enter in maintenance mode and only data with no redundancy will remain accessible.
Answers
D.
The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.
D.
The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.
Answers
Suggested answer: B

Explanation:

https://blogs.vmware.com/virtualblocks/2020/02/06/what-happens-vsan-host-in-maintenance-mode/ Let's take a look at a few unique scenarios with regard to maintenance mode. First, let's see what will happen if you have 6 hosts within your cluster, you have applied a policy containing FTT=2/RAID-6, and you want to place a host in maintenance mode using the 'Full data migration' option. This means all the data residing on the host will be evacuated to another host within the cluster. With this type of data configuration, the system will prompt you to add an additional host to the cluster in order to preserve the policy compliance. The policy will always require there must be two failures that can be tolerated, even during cluster reduction due to maintenance mode removing a host. Note that a minimum of six hosts is required to support a storage policy with RAID-6(FTT=2) erasure coding

asked 16/09/2024
Ruggero Pozza
38 questions

An administrator is tasked with sharing storage from one vSAN cluster to another vSAN cluster. SPBM management must be preserved end-to-end, and the policy must be applied by the source vSAN cluster which is storing the dat

a. Both vSAN clusters are managed by the same vCenter server.

What should the administrator configure?

Become a Premium Member for full access
Unlock Premium Member  Unlock Premium Member

An administrator of ''vsan-prod'' cluster noticed the witness components of VMs are flagged as absent after a failed attempt to replace the vSAN Witness Host.

Which action should the administrator take to resolve this issue?

A.
Upgrading the vSAN on-disk format
A.
Upgrading the vSAN on-disk format
Answers
B.
Running the vSAN Skyline Health check to ensure there are vSAN Object Health errors and executing the Repair Object Immediately option
B.
Running the vSAN Skyline Health check to ensure there are vSAN Object Health errors and executing the Repair Object Immediately option
Answers
C.
Using the RVC command: vsan.resync_dashboard ~/computers/vsan-prod
C.
Using the RVC command: vsan.resync_dashboard ~/computers/vsan-prod
Answers
D.
Placing the vSAN Witness Host in Maintenance Mode and adding to the vSAN cluster
D.
Placing the vSAN Witness Host in Maintenance Mode and adding to the vSAN cluster
Answers
Suggested answer: B
asked 16/09/2024
Stian Godoe
42 questions

An architect is tasked to design a VMware Horizon Solution with vSAN. The architect needs to use a solution to host the user's profile shares in a highly available manner, and it must be guest OS independent.

Which solution will match these requirements?

A.
Cluster out of the box
A.
Cluster out of the box
Answers
B.
Cluster in a box
B.
Cluster in a box
Answers
C.
NFS on vSAN
C.
NFS on vSAN
Answers
D.
iSCSI on vSAN
D.
iSCSI on vSAN
Answers
Suggested answer: C

Explanation:

Os independent is the requirements and High Availability. So vSAN 7 enable NFS and SMB on s SPBM cluster in wich Windows, Linux and MAC could have user profile with business continuity. Ref: https://core.vmware.com/blog/redirecting-user-profiles-and-data-using-fslogix-and-vsan-file-services

asked 16/09/2024
Aung Zin
41 questions

A vSAN policy has been configured with Erasure Coding on a vSAN stretched cluster.

Which RAID level and FTT setting have been specified?

Become a Premium Member for full access
Unlock Premium Member  Unlock Premium Member

An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu.

Which solution mandates the use of VMware vSAN?

A.
VMware Cloud Foundation
A.
VMware Cloud Foundation
Answers
B.
VMware Horizon
B.
VMware Horizon
Answers
C.
VMware Tanzu
C.
VMware Tanzu
Answers
D.
VMware vRealize Automation
D.
VMware vRealize Automation
Answers
Suggested answer: A

Explanation:

https://docs.vmware.com/en/VMware-Cloud-Foundation/3.10/vcf-deploy/GUID-E493608B-D4B6-4C98-96CA-5D2D723ACE55.html

asked 16/09/2024
Jatuchot Siriwongsilp
41 questions

An administrator is setting up vSAN file services on a vSAN cluster but is unable to join the vSAN File Services to the domain.

Which two possible reasons could explain this failure? (Choose two.)

Become a Premium Member for full access
Unlock Premium Member  Unlock Premium Member

A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1.

During the discovery phase, the consultant found the following information about the existing environment:

* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.

* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.

* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.

* The vSAN Cluster has the following configuration:

- vSAN version: 6.6.1

- Number of vSAN nodes: 10

- Encryption: enabled

- Deduplication and Compression: enabled

- vSAN Capacity Utilization: 60%

* Each vSAN node has the following configuration:

- VMware vSphere ESXi version: 6.5 Update 3

- CPU: 2 processors, 20 cores

- RAM: 768GB RAM.

- Disk: 2 Cache SSDs and 6 Capacity SSDs

- Network: 4 x 10GbE

Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)

A.
The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.
A.
The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.
Answers
B.
The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.
B.
The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.
Answers
C.
The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).
C.
The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).
Answers
D.
The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.
D.
The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.
Answers
E.
The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).
E.
The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).
Answers
F.
The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.
F.
The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.
Answers
Suggested answer: A, C, D

Explanation:

https://blogs.vmware.com/virtualblocks/2018/10/29/a-closer-look-at-emm/

asked 16/09/2024
Muhammad Waheed
41 questions

An architect is working with vSAN and setting the fault domains to support FTT=1.

How many fault domains will be needed?

A.
2
A.
2
Answers
B.
3
B.
3
Answers
C.
4
C.
4
Answers
D.
1
D.
1
Answers
Suggested answer: B
asked 16/09/2024
Matt Harrold
44 questions

An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.

Which step should be performed to exit the locked state?

A.
Manually replace the Host Encryption Key (HEK) of each affected host.
A.
Manually replace the Host Encryption Key (HEK) of each affected host.
Answers
B.
Restore the communication with the KMS server, and re-establish the trust relationship.
B.
Restore the communication with the KMS server, and re-establish the trust relationship.
Answers
C.
Replace the caching device in each affected disk group.
C.
Replace the caching device in each affected disk group.
Answers
D.
Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
D.
Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
Answers
Suggested answer: B

Explanation:

https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-monitoring.doc/GUID-084B3888-499F-4CD0-8954-A149560B1534.html

asked 16/09/2024
Kaan K
37 questions