ExamGecko
Home / DELL / D-XTR-DS-A-24
Ask Question

D-XTR-DS-A-24: Dell XtremIO Design Achievement

Vendor:
Exam Questions:
60
 Learners
  2.370
Last Updated
April - 2025
Language
English
2 Quizzes
PDF | VPLUS

The D-XTR-DS-A-24 also known as Dell EMC XtremIO Design Achievement, this exam is crucial for professionals in the field of Dell EMC XtremIO Design. To increase your chances of passing, practicing with real exam questions shared by those who have succeeded can be invaluable. In this guide, we’ll provide you with practice test questions and answers, offering insights directly from candidates who have already passed the exam.

Why Use D-XTR-DS-A-24 Practice Test?

  • Real Exam Experience: Our practice tests accurately replicate the format and difficulty of the actual D-XTR-DS-A-24 exam, providing you with a realistic preparation experience.

  • Identify Knowledge Gaps: Practicing with these tests helps you identify areas where you need more study, allowing you to focus your efforts effectively.

  • Boost Confidence: Regular practice with exam-like questions builds your confidence and reduces test anxiety.

  • Track Your Progress: Monitor your performance over time to see your improvement and adjust your study plan accordingly.

Key Features of D-XTR-DS-A-24 Practice Test:

  • Up-to-Date Content: Our community ensures that the questions are regularly updated to reflect the latest exam objectives and technology trends.

  • Detailed Explanations: Each question comes with detailed explanations, helping you understand the correct answers and learn from any mistakes.

  • Comprehensive Coverage: The practice tests cover all key topics of the D-XTR-DS-A-24 exam, including:

    • XtremIO and X2 Operations and Management
    • Host Configurations in XtremIO and X2 Environments
    • XtremIO X2 Data Replication
    • XtremIO X2 Optimization and Performance Management
    • Positioning XtremIO and X2
    • Designing an XtremIO X2 Solution
  • Customizable Practice: Create your own practice sessions based on specific topics or difficulty levels to tailor your study experience to your needs.

Exam Details:

  • Exam Number: D-XTR-DS-A-24

  • Exam Name: Dell EMC XtremIO Design Achievement

  • Length of Test: 90 minutes

  • Exam Format: Web-based with multiple-choice, multiple-response, drag-and-drop, and point-and-click questions

  • Exam Language: English

  • Number of Questions: 60 questions

  • Passing Score: 70%

Use the member-shared D-XTR-DS-A-24 Practice Tests to ensure you're fully prepared for your certification exam. Start practicing today and take a significant step towards achieving your certification goals!

DELL D-XTR-DS-A-24 Practice Tests

Related questions

A customer's environment is expected to grow significantly (more than 150 TB physical capacity) over the next year. Which solution should be recommended?

Start with X2-R cluster and add additional X2-R X-Bricks as needed
Start with X2-R cluster and add additional X2-R X-Bricks as needed
Start with a four X-Brick X2-S cluster and add additional X2-S X-Bricks as needed
Start with a four X-Brick X2-S cluster and add additional X2-S X-Bricks as needed
Start with X2-R cluster and add additional X2-S X-Bricks as needed
Start with X2-R cluster and add additional X2-S X-Bricks as needed
Start with X2-S cluster and add additional X2-S X-Bricks as needed
Start with X2-S cluster and add additional X2-S X-Bricks as needed
Suggested answer: A
Explanation:

For environments expected to grow significantly (more than 150 TB physical capacity), it is better to start with an X2-R cluster and add additional X2-R X-Bricks as needed. X2-R configurations are designed for a variety of use cases and can handle larger capacities and high-performance requirements.

asked 16/09/2024
Matthew Farrington
40 questions

An XtremlO administrator wants to understand the I/O transfer process. What are the parts of a typical I/O transfer?

Become a Premium Member for full access
  Unlock Premium Member

What is a benefit of XtremIO All Flash arrays?

Become a Premium Member for full access
  Unlock Premium Member

What are the I/O Elevators?

1/O scheduling algorithm which controls how I/O operations are submitted to storage.
1/O scheduling algorithm which controls how I/O operations are submitted to storage.
The maximum number of consecutive 'sequential' I/Os allowed to be submitted to storage.
The maximum number of consecutive 'sequential' I/Os allowed to be submitted to storage.
Setting which controls for how long the ESX host attempts to login to the iSCSI target before failing the login.
Setting which controls for how long the ESX host attempts to login to the iSCSI target before failing the login.
The amount of SCSI commands (including I/O requests) that can be handled by a storage device at a given time.
The amount of SCSI commands (including I/O requests) that can be handled by a storage device at a given time.
Suggested answer: A
Explanation:

Explore

I/O Elevators refer to the I/O scheduling algorithms used in operating systems to control how I/O operations are submitted to storage12. These algorithms, also known as elevators, determine the order in which I/O requests from different processes or devices are serviced by the underlying hardware, such as hard drives or solid-state drives (SSDs)12. The goal of these algorithms is to improve the efficiency of data access and reduce the time wasted by disk seeks3.

The other options provided are not typically referred to as I/O Elevators:

Option OB, ''The maximum number of consecutive 'sequential' I/Os allowed to be submitted to storage'', refers to a specific parameter of a storage system, not an I/O Elevator4.

Option OC, ''Setting which controls for how long the ESX host attempts to login to the iSCSI target before failing the login'', refers to a specific setting in ESXi host configuration, not an I/O Elevator567.

Option OD, ''The amount of SCSI commands (including I/O requests) that can be handled by a storage device at a given time'', refers to the command handling capacity of a storage device, not an I/O Elevator89.

Therefore, the verified answer is A. I/O scheduling algorithm which controls how I/O operations are submitted to storage, as it accurately describes what I/O Elevators are according to the Dell XtremIO Design Achievement document10 and other sources123.

asked 16/09/2024
Patricia Vontitte
42 questions

Refer to the exhibit.

DELL D-XTR-DS-A-24 image Question 3 22730 09162024193742000000

A customer wants to connect their Storage Controllers to Fibre Channel switches using as many Fibre Channel ports as possible. Which ports of each Storage Controller shown in the exhibit should be used?

3 and 4
3 and 4
2 and 3
2 and 3
1 and 2
1 and 2
1,2, 3, and 4
1,2, 3, and 4
Suggested answer: D
Explanation:

To maximize the connectivity between Storage Controllers and Fibre Channel switches, all available ports should be utilized. This ensures redundancy and maximizes throughput. The exhibit provided shows a Storage Controller with four ports labeled 1, 2, 3, and 4. Without specific design documents, the general best practice is to use all available ports for such connections, assuming the ports are configured for Fibre Channel traffic and the infrastructure supports it.

General best practices for Fibre Channel connectivity and port usage are discussed in various Dell EMC documents, such as the ''Introduction to XtremIO X2 Storage Array'' and ''Configuring Fibre Channel Storage Arrays'' documents12.

Specific port configurations and their usage would be detailed in the Dell XtremIO Design documents, which would provide definitive guidance on which ports to use for connecting to Fibre Channel switches.

asked 16/09/2024
Christian Gyssels
46 questions

XtremlO encrypts data that is stored on which drive?

Storage Controller and DAE
Storage Controller and DAE
Storage Controller only
Storage Controller only
Physical XMS, Storage Controller, and DAE
Physical XMS, Storage Controller, and DAE
DAE only
DAE only
Suggested answer: D
Explanation:

The Dell EMC XtremIO X2 Storage Array uses Data at Rest Encryption (D@RE) to encrypt data. This encryption occurs on the Self Encrypting Drives (SEDs) within the Data Availability Enclosures (DAE). The DAEs house the physical drives where the actual data is stored and encrypted1.

Introduction to Dell EMC XtremIO X2 Storage Array document2.

Dell EMC XtremIO v6.3 document1.

asked 16/09/2024
John Eestermans
36 questions

A storage administrator is configuring SAN switches and zoning to connect a four X-Brick XtremlO array. A VMware ESXi server is hosted on a blade chassis with 16 HBA ports.

In addition, the SAN consists of two separate SAN switches.

What is the recommended XtremlO best practice for zoning?

Become a Premium Member for full access
  Unlock Premium Member

What should the I/O size be set to in a VMware VDI solution utilizing VAAI XCOPY on XtremIO?

Become a Premium Member for full access
  Unlock Premium Member

A customer is adding a new volume to their XtremlO environment using the RESTful API. When attempting to create the volume, a response code of 400 is returned. What is the cause of this response code?

Become a Premium Member for full access
  Unlock Premium Member

How many DAE Row Controllers are present within the DAE chassis of an XtremIO X2 cluster?

Become a Premium Member for full access
  Unlock Premium Member