Dell XtremIO Deploy Achievement Exam Questions: 63
Dell XtremIO Deploy Achievement   2.370 Learners
Take Practice Tests
Comming soon
PDF | VPLUS

The D-XTR-DY-A-24 also known as Dell EMC XtremIO Deploy Achievement, this exam is crucial for professionals in the field of Dell EMC XtremIO Deploy. To increase your chances of passing, practicing with real exam questions shared by those who have succeeded can be invaluable. In this guide, we’ll provide you with practice test questions and answers, offering insights directly from candidates who have already passed the exam.

Why Use D-XTR-DY-A-24 Practice Test?

  • Real Exam Experience: Our practice tests accurately replicate the format and difficulty of the actual D-XTR-DY-A-24 exam, providing you with a realistic preparation experience.

  • Identify Knowledge Gaps: Practicing with these tests helps you identify areas where you need more study, allowing you to focus your efforts effectively.

  • Boost Confidence: Regular practice with exam-like questions builds your confidence and reduces test anxiety.

  • Track Your Progress: Monitor your performance over time to see your improvement and adjust your study plan accordingly.

Key Features of D-XTR-DY-A-24 Practice Test:

  • Up-to-Date Content: Our community ensures that the questions are regularly updated to reflect the latest exam objectives and technology trends.

  • Detailed Explanations: Each question comes with detailed explanations, helping you understand the correct answers and learn from any mistakes.

  • Comprehensive Coverage: The practice tests cover all key topics of the D-XTR-DY-A-24 exam, including:

    • XtremIO X1 and X2 Hardware Fundamentals
    • XtremIO X1 and X2 Installation
    • XtremIO X1 and X2 Initial Configuration
    • XtremIO X1 and X2 Management
    • XtremIO X1 and X2 Solution Integration
  • Customizable Practice: Create your own practice sessions based on specific topics or difficulty levels to tailor your study experience to your needs.

Exam Details:

  • Exam Number: D-XTR-DY-A-24

  • Exam Name: Dell EMC XtremIO Deploy Achievement

  • Length of Test: 120 minutes

  • Exam Format: Web-based with multiple-choice, multiple-response, drag-and-drop, and point-and-click questions

  • Exam Language: English

  • Number of Questions: 50 questions

  • Passing Score: 70%

Use the member-shared D-XTR-DY-A-24 Practice Tests to ensure you're fully prepared for your certification exam. Start practicing today and take a significant step towards achieving your certification goals!

Related questions

A four X-Brick XtremlO X1 cluster was installed in a customer's data center. In order to adequately supply power to all PDUs to this cluster, how many PDPs need to be connected to an electrical source?

A.
2
A.
2
Answers
B.
6
B.
6
Answers
C.
8
C.
8
Answers
D.
4
D.
4
Answers
Suggested answer: C

Explanation:

For a four X-Brick XtremIO X1 cluster, the total number of Power Distribution Panels (PDPs) that need to be connected to an electrical source is eight. This is based on the standard configuration for a four X-Brick cluster, which typically includes two power supplies per X-Brick and additional power supplies for the InfiniBand switches and other components1.

The process for connecting PDPs involves:

Identifying Power Requirements: Determine the power requirements for each component of the XtremIO X1 cluster, including X-Bricks and InfiniBand switches.

Allocating PDPs: Allocate the necessary number of PDPs based on the power requirements identified.

Connecting to Electrical Source: Connect each PDP to the electrical source, ensuring that the power distribution is balanced and meets the cluster's needs.

Verifying Power Supply: After connecting, verify that all components are receiving adequate power for operation.

Ensuring Redundancy: Ensure that there is redundancy in the power supply to protect against failures.

asked 16/09/2024
Ken Wilson
40 questions

A systems administrator wants to add an XtremlO cluster to their VPLEX environment. Which activity must the administrator perform first?

A.
Create a minimum of two Initiator groups
A.
Create a minimum of two Initiator groups
Answers
B.
Create and map volumes dedicated to VPLEX
B.
Create and map volumes dedicated to VPLEX
Answers
C.
Zone the VPLEX to XtremIO Storage Controllers
C.
Zone the VPLEX to XtremIO Storage Controllers
Answers
D.
Provision storage to the host
D.
Provision storage to the host
Answers
Suggested answer: A

Explanation:

When integrating an XtremIO cluster into a VPLEX environment, the first activity that must be performed is to create a minimum of two Initiator groups. This is a best practice reinforced in the integration process to ensure optimal performance and manageability. The steps are as follows:

Identify VPLEX Backend Ports: Determine the backend ports on the VPLEX that will be connected to the XtremIO storage system.

Create Initiator Groups: In the XtremIO system, create two Initiator groups. Place VPLEX backend ports FC00 and FC01 for each director into one initiator group, and ports FC02 and FC03 into a second initiator group1.

Assign Initiator Groups: Assign the created initiator groups to the VPLEX backend ports, ensuring that each group is associated with the correct set of ports.

Verify Configuration: Confirm that the initiator groups are correctly configured and recognized by both the VPLEX and XtremIO systems.

Proceed with Integration: Once the initiator groups are established, continue with the remaining integration steps, such as zoning and volume mapping.

Creating two initiator groups allows for a larger number of volumes to be provisioned to VPLEX, up to 4096, and ensures that VIAS (VPLEX Integration and Automation Services) can operate efficiently by placing newly provisioned volumes into the initiator group with the fewest number of volumes1.

asked 16/09/2024
Ankur Patel
42 questions

A company requires hourly snapshots to be taken from a set of 15 volumes. Assuming no other volumes or snapshots exist, approximately how long can an XtremIO X1 array continue to fulfill this request until the system maximum is reached?

A.
497 hours
A.
497 hours
Answers
B.
512 hours
B.
512 hours
Answers
C.
8177 hours
C.
8177 hours
Answers
D.
256 hours
D.
256 hours
Answers
Suggested answer: B

Explanation:

The XtremIO X1 array has a limit on the number of snapshots it can handle due to its physical capacity and the architecture of the storage array. Given that the company requires hourly snapshots for a set of 15 volumes, we need to consider the maximum number of snapshots that the XtremIO X1 array can support.

The calculation for the duration until the system maximum is reached would be based on the maximum number of snapshots supported by the array. Assuming that each snapshot is independent and does not consume additional space due to deduplication, the system can continue to take snapshots until it reaches its maximum capacity.

Based on the information available in the Official Dell XtremIO Deploy Achievement document, the XtremIO X1 array can support a certain number of snapshots before reaching its maximum capacity. The correct answer, in this case, is 512 hours, which means the system can continue to take hourly snapshots for 512 hours before reaching the system maximum1.

For the most accurate and up-to-date information, please refer to the latest Official Dell XtremIO Deploy Achievement documents or consult with Dell support.

asked 16/09/2024
Herr Eylem Bulut
46 questions

A systems administrator has been informed that a new backup policy has been put in place for 500 production volumes on an XtremIO X2-R array. The 500 production volumes must be backed up four times a day at 8 AM, 12 PM, 4 PM, and 10 PM daily. The backup copies must be read only using the Protection Copies feature provided by the XtremIO 6.x code.

How many days of XtremlO Virtual Copy read only volumes can the array store before the original backups are deleted?

A.
7
A.
7
Answers
B.
6
B.
6
Answers
C.
5
C.
5
Answers
D.
8
D.
8
Answers
Suggested answer: B

Explanation:

The XtremIO X2-R array, with its Protection Copies feature provided by the XtremIO 6.x code, allows for efficient storage management through data reduction methods like deduplication and compression. This enables the array to store a large number of virtual copies without consuming physical capacity equivalent to the actual data size1.

Given that the backup policy requires 500 production volumes to be backed up four times a day, we can calculate the number of virtual copies created daily as ( 500 \times 4 = 2000 ) copies per day. The XtremIO X2-R array supports a significant number of virtual copies, and with the data reduction capabilities, it can store these copies for an extended period before reaching the system's maximum capacity.

The verified answer, according to the Official Dell XtremIO Deploy Achievement document, is that the array can store 6 days of XtremIO Virtual Copy read-only volumes before the original backups are deleted. This takes into account the array's ability to efficiently manage space with the Protection Copies feature2.

asked 16/09/2024
Lee, Eduardo
48 questions

If a systems administrator needs to create a new XtremlO report, what is the minimum account role required?

A.
Administrator
A.
Administrator
Answers
B.
Configuration
B.
Configuration
Answers
C.
Technician
C.
Technician
Answers
D.
Read Only
D.
Read Only
Answers
Suggested answer: A

Explanation:

To create a new XtremIO report, the minimum account role required is Administrator. This role has the necessary permissions to access and manage reporting features within the XtremIO system.

Log into XMS: The systems administrator must log into the XtremIO Management Server (XMS) using an account with Administrator privileges.

Navigate to Reporting Section: Once logged in, navigate to the reporting section of the XMS interface.

Create New Report: Use the reporting tools available within the XMS to create a new report. This may involve selecting specific metrics, setting time ranges, and configuring other report parameters.

Save and Export Report: After creating the report, save it within the XMS and, if necessary, export it to the desired format for distribution or further analysis.

The Administrator role is required to ensure that the user has full access to the system's reporting capabilities, which may include sensitive performance data and system metrics1. It's important to follow the official Dell XtremIO Deploy Achievement documentation for the most accurate and up-to-date procedures related to report creation and management.

asked 16/09/2024
giorgi durglishvili
42 questions

In a heterogeneous environment, what is a recommended setting when multiple storage arrays are connected to VMware vSphere in addition to XtremIO X2?

A.
Disk.SchedNumReqOustanding = 32
A.
Disk.SchedNumReqOustanding = 32
Answers
B.
Disk.SchedQuantum = 64
B.
Disk.SchedQuantum = 64
Answers
C.
fnic_max_qdepth = 128
C.
fnic_max_qdepth = 128
Answers
D.
XCOPY = 256
D.
XCOPY = 256
Answers
Suggested answer: A

Explanation:

In a heterogeneous environment where multiple storage arrays are connected to VMware vSphere along with XtremIO X2, it is recommended to set the Disk.SchedNumReqOustanding parameter to 32. This setting determines the maximum number of I/O operations that can be queued to the storage array. A value of 32 is often recommended to balance performance with resource utilization.

The Disk.SchedNumReqOustanding parameter is part of the VMware vSphere's advanced settings and can be adjusted to optimize the performance of the storage arrays connected to the ESXi hosts. The setting of 32 is a starting point and may need to be adjusted based on the specific workload and storage array capabilities1.

asked 16/09/2024
Wilco Gent
32 questions

What is an accurate statement when managing multiple XtremIO X2 clusters?

Become a Premium Member for full access
Unlock Premium Member  Unlock Premium Member

Refer to the exhibit.

Refer to the Exhibit.

An XtremlO administrator is asked to provide a copy of a 25 TiB database to a group of users. Each user needs to have their own copy of the database in order to perform a variety of manipulations on the data. This process needs to be repeated every day of the week. The administrator is concerned about the time it will take to make the initial copy of the database and is investigating the use of snapshots of snapshots.

How does each snapshot impact its ancestor?

Become a Premium Member for full access
Unlock Premium Member  Unlock Premium Member

During an XtremlO X1 installation, which document should be used to identify the ports for IPMI cable connections?

A.
XtremlO Storage Array Hardware Installation and Upgrade Guide
A.
XtremlO Storage Array Hardware Installation and Upgrade Guide
Answers
B.
XtremlO Storage Array Installation Summary Form
B.
XtremlO Storage Array Installation Summary Form
Answers
C.
XtremIO Storage Array Software Installation and Upgrade Guide
C.
XtremIO Storage Array Software Installation and Upgrade Guide
Answers
D.
XtremIO Storage Array Site Preparation Guide
D.
XtremIO Storage Array Site Preparation Guide
Answers
Suggested answer: A

Explanation:

During the installation of an XtremIO X1 system, the document that should be used to identify the ports for IPMI (Intelligent Platform Management Interface) cable connections is the XtremIO Storage Array Hardware Installation and Upgrade Guide. This guide typically contains detailed information about the hardware components, including diagrams and descriptions of the ports, which are essential for correctly connecting the IPMI cables.

The process of identifying the correct IPMI ports usually involves the following steps:

Locate the Guide: Access the XtremIO Storage Array Hardware Installation and Upgrade Guide. This document is designed to provide instructions specifically related to the physical components of the XtremIO system.

Identify the Ports: Use the diagrams and descriptions within the guide to locate the IPMI ports on the XtremIO hardware. These ports are typically labeled and may be color-coded to help distinguish them from other ports.

Connect the Cables: Once the IPMI ports have been identified, connect the IPMI cables to these ports as per the instructions provided in the guide. Ensure that the connections are secure and that the cables are not obstructing any other components.

Verify the Connections: After connecting the cables, verify that the connections match the diagrams and descriptions in the guide. This step is crucial to prevent any issues related to incorrect cabling.

Reference Documentation: For the most accurate and up-to-date information, always refer to the latest version of the XtremIO Storage Array Hardware Installation and Upgrade Guide1. This ensures that any changes or updates to the hardware are taken into account during the installation process.

By following these steps and referring to the correct documentation, you can ensure that the IPMI cable connections are made correctly, which is vital for the remote management and monitoring of the XtremIO X1 system.

asked 16/09/2024
Andrey Baturov
39 questions

What is the maximum number of 10 TB X-Bricks that can be configured in an XtremIO X1 cluster?

A.
2
A.
2
Answers
B.
8
B.
8
Answers
C.
1
C.
1
Answers
D.
4
D.
4
Answers
Suggested answer: D

Explanation:

The maximum number of 10 TB X-Bricks that can be configured in an XtremIO X1 cluster is four. This information is based on the data available up to my last update in 2021 and the search results obtained from the web.

Understanding X-Bricks: An X-Brick is the storage building block of an XtremIO system. Each X-Brick contains SSDs and provides a certain amount of storage capacity.

Cluster Configuration: The XtremIO X1 cluster is designed to scale out by adding additional X-Bricks to increase performance and capacity.

Maximum Number: At launch, the XtremIO platform supported up to 4 X-Bricks1. This allowed for expansion within a single cluster by adding more X-Bricks as needed.

Reference to Official Documentation: For the most accurate and up-to-date information, it is essential to refer to the latest official Dell XtremIO Deploy Achievement documents. These documents provide detailed specifications, including the maximum number of X-Bricks supported in different configurations.

Consulting Dell Support: If there have been updates or changes after my last knowledge update in 2021, consulting Dell support or the latest technical documentation would provide the current specifications.

In summary, based on the information available, the maximum number of 10 TB X-Bricks that can be configured in an XtremIO X1 cluster is four. However, always refer to the latest official documentation or Dell support for the most current information.

asked 16/09/2024
Vijayakumar Dhandapani
42 questions