ExamGecko
Home Home / DELL / D-PWF-DS-23
Ask QuestionAsk Question

D-PWF-DS-23: Dell PowerFlex Design 2023

Dell PowerFlex Design 2023 Vendor:
Dell PowerFlex Design 2023 Exam Questions:
40
Dell PowerFlex Design 2023  Learners
  2.370
Dell PowerFlex Design 2023 Last Updated
January - 2025
Dell PowerFlex Design 2023 Language
English
1 Quizzes
PDF | VPLUS

The D-PWF-DS-23 also known as Dell EMC PowerFlex Design 2023, this exam is crucial for professionals in the field of Dell EMC PowerFlex Design. To increase your chances of passing, practicing with real exam questions shared by those who have succeeded can be invaluable. In this guide, we’ll provide you with practice test questions and answers, offering insights directly from candidates who have already passed the exam.

Why Use D-PWF-DS-23 Practice Test?

  • Real Exam Experience: Our practice tests accurately replicate the format and difficulty of the actual D-PWF-DS-23 exam, providing you with a realistic preparation experience.

  • Identify Knowledge Gaps: Practicing with these tests helps you identify areas where you need more study, allowing you to focus your efforts effectively.

  • Boost Confidence: Regular practice with exam-like questions builds your confidence and reduces test anxiety.

  • Track Your Progress: Monitor your performance over time to see your improvement and adjust your study plan accordingly.

Key Features of D-PWF-DS-23 Practice Test:

  • Up-to-Date Content: Our community ensures that the questions are regularly updated to reflect the latest exam objectives and technology trends.

  • Detailed Explanations: Each question comes with detailed explanations, helping you understand the correct answers and learn from any mistakes.

  • Comprehensive Coverage: The practice tests cover all key topics of the D-PWF-DS-23 exam, including:

    • PowerFlex Foundations
    • PowerFlex Solution Design
    • PowerFlex Objects Configuration
    • PowerFlex Nodes and Volumes Configuration
    • PowerFlex Solutions Integration and Troubleshooting
  • Customizable Practice: Create your own practice sessions based on specific topics or difficulty levels to tailor your study experience to your needs.

Exam Details:

  • Exam Number: D-PWF-DS-23

  • Exam Name: Dell EMC PowerFlex Design 2023

  • Length of Test: 90 minutes

  • Exam Format: Web-based with multiple-choice, multiple-response, drag-and-drop, and point-and-click questions

  • Exam Language: English

  • Number of Questions: 40 questions

  • Passing Score: 70%

Use the member-shared D-PWF-DS-23 Practice Tests to ensure you're fully prepared for your certification exam. Start practicing today and take a significant step towards achieving your certification goals!

DELL D-PWF-DS-23 Practice Tests

Related questions

An administrator is adding an NVMe device to an existing storage pool They provide the following details in the Add Storage Device to SDS dialog box

* Device Path /dev/disk/by-id'Dell_Express_Flash_NVMe_PM1725_V6TB_SFF_ _S2JPNA0J500141

* Device Name NVMe A. 1.6 TB

* Storage Pool SP-1

What is the result of this action'?

A.
The device addition fails due to an invalid path
A.
The device addition fails due to an invalid path
Answers
B.
The device is named 'NVMeAt 6 TB' and added to the Storage Pool 'SP-1'.
B.
The device is named 'NVMeAt 6 TB' and added to the Storage Pool 'SP-1'.
Answers
C.
The device name is truncated to 'NVMe' and added lo the Storage Pool 'SP-t'
C.
The device name is truncated to 'NVMe' and added lo the Storage Pool 'SP-t'
Answers
D.
The device addition tails due to invalid characters in the name
D.
The device addition tails due to invalid characters in the name
Answers
Suggested answer: A

Explanation:

When adding an NVMe device to an existing storage pool in PowerFlex, the details provided in the ''Add Storage Device to SDS'' dialog box must be accurate and follow the correct syntax. In the scenario provided, the device path contains an invalid character (an apostrophe) and an incorrect format, which would cause the device addition to fail.

Here's a breakdown of the process and where the error occurs:

Device Path: The device path should be a valid Linux device path, typically starting with/dev/disk/by-id/.The path provided contains an apostrophe (') which is not a valid character in Linux file paths and would result in an error1.

Device Name: The device name should be a simple identifier without spaces or special characters. The name provided, ''NVMe A.1.6 TB'', contains spaces and periods, which are not typical for device names and could potentially lead to issues, although the primary cause of failure is the invalid device path1.

Storage Pool: The storage pool name ''SP-1'' is a valid identifier, but it is contingent on the correct device path and name for the device to be added successfully.

The result of the action, given the invalid device path, would be that the device addition fails. It is crucial to ensure that all details entered in the dialog box adhere to the expected formats and do not contain invalid characters to avoid such failures.

This explanation is based on the standard practices for device path naming conventions in Linux systems and the configuration guidelines for PowerFlex systems as described in Dell's official documentation1. Correcting the device path by removing the invalid character and ensuring the proper format would resolve the issue and allow the device to be added to the storage pool successfully.

asked 16/09/2024
Daniel Martos
44 questions

DRAG DROP

What is the correct sequence of steps to create an FG Storage Pool within a PowerFlex system?

Question 12
Correct answer: Question 12

Explanation:

Create a Protection Domain.

Create a Storage Pool.

Add the SDSs.

Add the SSD devices to the Pool.

Create an Acceleration Pool.

Add the DAX devices to the Pool.


asked 16/09/2024
Tobias Barcelos
42 questions

An administrator is creating a NAS server with a Standalone Windows server. Creation of trie NAS server fails What is the cause of the failure?

A.
A Storage Pool lor NAS has not been created
A.
A Storage Pool lor NAS has not been created
Answers
B.
The NAS server is using the same VLAN as block storage networks
B.
The NAS server is using the same VLAN as block storage networks
Answers
C.
DNS was not defined in the NAS server creation wizard
C.
DNS was not defined in the NAS server creation wizard
Answers
D.
FSN has not been added to the cluster
D.
FSN has not been added to the cluster
Answers
Suggested answer: A

Explanation:

The creation of a NAS server requires a dedicated storage pool. If a storage pool specifically for NAS has not been created, the NAS server creation will fail. This is because the NAS server needs to allocate space from a storage pool to store the file system data. Without a designated storage pool, the NAS server cannot be configured properly1.

The other options, while important for the operation and integration of a NAS server, are not directly related to the creation process itself. For instance, using the same VLAN as block storage networks (Option B) may lead to network conflicts, but it would not prevent the creation of the NAS server. Similarly, not defining DNS in the NAS server creation wizard (Option C) could cause resolution issues later on, but it is not a prerequisite for the creation of the NAS server. Lastly, while adding FSN to the cluster (Option D) is a necessary step for enabling file system services, it is not the cause of the NAS server creation failure in this context.

Therefore, the correct answer is A. A Storage Pool for NAS has not been created, as it is a fundamental requirement for the NAS server creation process in a PowerFlex environment.

asked 16/09/2024
Wislon Pereira
36 questions

What is the default value of paths per volume when adding an NVMe host?

A.
8
A.
8
Answers
B.
4
B.
4
Answers
C.
2
C.
2
Answers
D.
1
D.
1
Answers
Suggested answer: A

Explanation:

The default value of paths per volume when adding an NVMe host to a PowerFlex system is 8. This setting is relevant for the configuration of multipathing, which is a method used to provide redundancy and increase availability for storage environments. When you add an NVMe host, the system allows up to 8 paths per volume to be configured by default. This is particularly important in VMware ESXi environments, where multipathing can be configured to handle failover and load balancing of storage traffic.

The reference for this information is found in the Dell PowerFlex specification sheet, which outlines the maximum paths in the multipathing driver per volume as 8 for ESXi 7.0u31. This document provides detailed specifications and configurations for the PowerFlex system, ensuring that the information is aligned with Dell's official documentation and design guidelines for PowerFlex systems.

asked 16/09/2024
Bhavani Simhadri
29 questions

An administrator wants to delete a secure snapshot that was created 30 days ago and has a 60-day expiration period The snapshot was created by a snapshot policy and lock is enabled How can the administrator delete the snapshot?

A.
Use the Dual Signature Policy agreement with Dell
A.
Use the Dual Signature Policy agreement with Dell
Answers
B.
Disable Uie snapshot policy lock on the snapshot.
B.
Disable Uie snapshot policy lock on the snapshot.
Answers
C.
Change the snapshot expiration period to 30 days
C.
Change the snapshot expiration period to 30 days
Answers
Suggested answer: B

Explanation:

Secure snapshots in PowerFlex are controlled by policies that define their retention and expiration periods. If a snapshot has a lock enabled, it cannot be deleted until the lock is disabled. The lock is a security feature that prevents accidental or unauthorized deletion of the snapshot before its intended retention period1.

To delete a secure snapshot that is still within its expiration period but needs to be removed, the administrator must first disable the snapshot policy lock. Here are the general steps to do so:

Access PowerFlex Manager.

Navigate to the Snapshots section.

Locate the specific snapshot that needs to be deleted.

Disable the lock on the snapshot policy associated with the snapshot.

Once the lock is disabled, the snapshot can be deleted manually.

Changing the snapshot expiration period to 30 days (Option C) would not affect the ability to delete the snapshot if the lock is still enabled. The Dual Signature Policy agreement with Dell (Option A) is not a standard procedure for deleting snapshots within PowerFlex and is not related to the administrative controls of snapshot policies.

Therefore, the correct answer is B. Disable the snapshot policy lock on the snapshot, as this action will allow the administrator to delete the snapshot before the expiration period, provided that the snapshot is no longer needed and can be safely removed from the system1.

asked 16/09/2024
KENEILWE DITHLAGE
42 questions

What is the maximum number of SDSs per protection domain of the PowerFlex rack?

A.
256
A.
256
Answers
B.
128
B.
128
Answers
C.
64
C.
64
Answers
Suggested answer: B

Explanation:

The maximum number of Storage Data Servers (SDSs) per protection domain in a PowerFlex rack is 1283. This is specified in the PowerFlex specification sheet and ensures that each protection domain can provide data protection for a significant number of SDSs, allowing for scalability and resilience within the PowerFlex infrastructure.

asked 16/09/2024
Jonathan Ang
36 questions

Which component of the PowerFlex cluster provides server metrics such as telemetry thermal data and sets the server configuration profile?

A.
PowerFlex Manager
A.
PowerFlex Manager
Answers
B.
CloudLink Center
B.
CloudLink Center
Answers
C.
VMware ESXi
C.
VMware ESXi
Answers
D.
iDRAC
D.
iDRAC
Answers
Suggested answer: D

Explanation:

The Integrated Dell Remote Access Controller (iDRAC) is the component within a PowerFlex cluster that provides server metrics, including telemetry and thermal data, and allows for setting the server configuration profile. iDRAC is an embedded system management hardware and software solution that provides remote management capabilities, system health monitoring, and recovery capabilities. It is a key component for server lifecycle management within the PowerFlex infrastructure1.

iDRAC operates independently from the server's CPU and operating system, enabling administrators to monitor server health and manage systems even when the server is turned off or unresponsive. It provides a comprehensive set of server management features, including:

Monitoring server health and managing power usage.

Accessing logs for troubleshooting and recovery.

Updating firmware and drivers.

Configuring hardware settings and server profiles.

These capabilities are essential for maintaining the reliability and performance of PowerFlex clusters, making iDRAC a critical component for server metrics and configuration management.

asked 16/09/2024
Jay Barre
37 questions

A volume has a snapshot policy assigned and snapshot creation is failing What is the cause of this issue?

A.
The requested snapshot is 126th in the vTree.
A.
The requested snapshot is 126th in the vTree.
Answers
B.
The snapshot name does not match the source volume.
B.
The snapshot name does not match the source volume.
Answers
C.
The snapshot is the 61st created by the policy
C.
The snapshot is the 61st created by the policy
Answers
D.
The storage pool has 32 000 volumes plus snapshots and is at its limit
D.
The storage pool has 32 000 volumes plus snapshots and is at its limit
Answers
Suggested answer: C

Explanation:

The cause of the snapshot creation failure when a volume has a snapshot policy assigned is likely because the snapshot is the 61st created by the policy. According to Dell PowerFlex documentation, of the 126 user-available snapshots per volume, sixty (60) can be used for policy-based snapshot scheduling1. This means that if the policy attempts to create a snapshot beyond this limit, it will fail.

Here's a step-by-step explanation of the issue:

Snapshot Policy Limit: Each volume in a PowerFlex system can have a maximum of 126 user-available snapshots. For policy-based snapshot scheduling, the limit is 60 snapshots per volume1.

Policy-Based Snapshot Creation: When a snapshot policy is in place, it will automatically attempt to create snapshots based on the defined schedule and retention levels.

Failure Point: If the snapshot policy tries to create a snapshot and it is the 61st snapshot for that volume, the creation will fail because it exceeds the limit set for policy-based snapshots1.

Resolution: To resolve this issue, the administrator would need to adjust the snapshot policy to ensure that it does not exceed the limit of 60 snapshots. This may involve modifying the retention levels or the frequency of snapshot creation.

This explanation is based on the snapshot policy details provided in the Dell PowerFlex documentation, which outlines the restrictions and uses of snapshots within the PowerFlex storage system1.

asked 16/09/2024
rita whitfield
38 questions

Which PowerFlex Manager activity can the System Admin role perform?

A.
Lifecycle operations
A.
Lifecycle operations
Answers
B.
Manage users
B.
Manage users
Answers
C.
Update certificates
C.
Update certificates
Answers
Suggested answer: A

Explanation:

The System Admin role in PowerFlex Manager is primarily responsible for performing lifecycle operations. This includes tasks such as deploying, configuring, and updating the PowerFlex system components. The role is designed to manage the operational aspects of the PowerFlex environment, ensuring that the system is running efficiently and is up to date1.

While managing users and updating certificates are important administrative tasks, they are typically associated with different roles within the PowerFlex Manager's user management system. For instance, managing users would fall under the purview of a User Admin role, which would handle the creation, modification, and deletion of user accounts. Updating certificates, on the other hand, would be more aligned with a Security Admin role, which would be responsible for maintaining the security aspects of the PowerFlex system, including certificate management1.

Therefore, the correct answer is A. Lifecycle operations, as it directly relates to the System Admin role's responsibilities within PowerFlex Manager.

asked 16/09/2024
Jonathan Hernández Hernández
31 questions

What is the purpose of tree quotas in PowerFlex?

Become a Premium Member for full access
Unlock Premium Member  Unlock Premium Member