CDCS-001: Certified Data Centre Specialist
GAQM
Exam Number: CDCS-001
Exam Name: Certified Data Centre Specialist
Length of test: 60 mins
Exam Format: Multiple-choice questions.
Exam Language: English
Number of questions in the actual exam: Maximum of 40 questions
Passing Score: 70% (28 out of 40 questions).
Topic Covered:
-
Selecting the Right Power, Space, and Network Connectivity for the Organization
-
DC Power and Redundant Cooling Systems
-
Concurrently Maintaining Power and Cooling Systems (N+1 AC power, N+1 cooling)
-
Site Monitoring and Security (Biometric Authentication, Key Cards, On-site Guards, Enhanced Security)
-
Data Centre Networking (Reducing Latency, Backbone Technologies, Global Cloud and Virtualization Services, IT Convergence)
This study guide should help you understand what to expect on CDCS-001 exam and includes a summary of the topics the exam might cover and links to additional resources. The information and materials in this document should help you focus your studies as you prepare for the exam.
Related questions
Every air distribution system has a ____________ system and a _________ system
Supply, Release
Supply, Return
Supply, Reverse
Maintenance, Regulation
Explanation:
Every air distribution system has a supply system, which delivers conditioned air to the space, and a return system, which collects the air from the space and returns it to the air handling unit. The return system is responsible for providing the necessary negative pressure in the space to ensure proper air circulation.
__________ represents the maximum power cable of being drawn by the equipment.
VA rating
Power rating
Star rating
Grade rating
Explanation:
Power rating represents the maximum power that can be drawn by the equipment. It is usually measured in watts (W) or kilowatts (kW) and represents the maximum amount of power that the equipment can consume without causing damage to the device or the power source.
VA rating (Volt-Ampere rating) is a measure of the apparent power in a circuit, which is the product of the voltage and current in the circuit. It is often used to describe the power handling capability of electronic devices and equipment.
Star rating is a rating system used to indicate the energy efficiency of electrical devices and equipment. The rating ranges from 1 to 5 stars, with 5 stars indicating the most energy-efficient device.
Grade rating is a rating system used to indicate the quality of electrical devices and equipment. It is used in different industry and can indicate the quality of electronic component and material used in equipment.
____________ is a systematic variation of the voltage wave form or a series of random voltage changes of small dimensions.
Voltage fluctuation
Voltage truncation
Frequency variation
Standby variation
Explanation:
Voltage fluctuation is a systematic variation of the voltage waveform or a series of random voltage changes of small dimensions that occur over a period of time. Voltage fluctuation can be caused by a variety of factors, such as changes in demand, changes in the power system, faults on the power system, or the switching of large loads.
Which type of Circuit Breaker uses an electromagnetic coil to pull a switch when a circuit carries too much current?
Thermal
Magnetic
Pull
Static
Explanation:
Magnetic circuit breakers use an electromagnetic coil to pull a switch when a circuit carries too much current, thus tripping the circuit and preventing it from exceeding its rated amperage.
The distance that a signal's energy can travel in the time it takes for one cycle to occur is called the signal's:
amplitude
frequency
wavelength
period
Explanation:
Wavelength is a measure of the distance that a signal's energy can travel in the time it takes for one cycle of the signal to occur. It is calculated by dividing the speed of light by the frequency of the signal. Wavelength is generally expressed in meters (m).
A typical data center load would consist of _____ (Choose 3)
Cooling equipment
Networking equipment
Power generator
Software
Computers
True or False: Human error is a major cause of data center downtime
True
False
Explanation:
Human error is a major cause of data center downtime. Human mistakes are one of the top causes of data center outages, accounting for around one-third of all downtime incidents. Common causes of human error in data centers include misconfiguration, inadequate maintenance, and improper security practices. To reduce the risk of human error, it is important to ensure that data center staff receive proper training, have adequate access control measures in place, and are familiar with best practices for data center operations.
Which type of outlet is used for non-computing devices?
Static
Grounding
Harmonic
Convenience
Explanation:
Convenience outlets, also known as duplex receptacles or wall outlets, are used to provide power to non-computing devices, such as lamps, televisions, and other household appliances. They are typically found in residential and commercial buildings and are connected to a circuit breaker or fuse for protection against overloading and electrical fires
Which one of the following is a Physical Security Device?
Access Key
Contactless smart card
Token card
Fiber optic cable
Explanation:
A contactless smart card is a physical security device that uses radio frequency identification (RFID) technology to identify and authenticate an individual. This type of card is used in a variety of applications, such as access control systems and digital payment systems. It is also used in physical access control systems, where the card is used to unlock doors or grant access to restricted areas.
Contactless smart cards are also used in building access systems, where the card is used to grant access to certain areas of the building.
Which one of the following is a disadvantage of Water Cooled System?
Question