ExamGecko
Home / VCE / 210-010 / List of questions
Ask Question

VCE 210-010 Practice Test - Questions Answers

List of questions

Question 1

Report Export Collapse

Which EMC software is required to upgrade code on a Vblock System 200 storage array?

Unisphere Service Manager
Unisphere Service Manager
Unisphere Server Utility
Unisphere Server Utility
VNX Installation Assistant
VNX Installation Assistant
Unisphere Client
Unisphere Client
Suggested answer: A
asked 23/09/2024
Hairul Isman Abdul Gaffar
38 questions

Question 2

Report Export Collapse

Which two statements are correct about Vblock System Release Certification Matrix (RCM) upgrades? (Choose two.)

The RCM must be applied by VCE certified resources.
The RCM must be applied by VCE certified resources.
When upgrading to a new RCM, all components may not require an upgrade.
When upgrading to a new RCM, all components may not require an upgrade.
The most recent RCM version must be applied.
The most recent RCM version must be applied.
An addendum to the RCM may be issued to address a bug or software issue.
An addendum to the RCM may be issued to address a bug or software issue.
Suggested answer: B, D
asked 23/09/2024
Veronica Puddu
54 questions

Question 3

Report Export Collapse

Which Cisco Catalyst switch is used for network management on a Vblock System 200?

Cisco Catalyst 2960
Cisco Catalyst 2960
Cisco Catalyst 3560
Cisco Catalyst 3560
Cisco Catalyst 3750
Cisco Catalyst 3750
Cisco Catalyst 4500
Cisco Catalyst 4500
Suggested answer: C
asked 23/09/2024
Andrea Di Giuseppe
34 questions

Question 4

Report Export Collapse

The implementation profile located in the Logical Configuration Survey (LCS) identifies if the customer will be using which two solutions? (Choose two.)

EMC SnapView
EMC SnapView
Cisco IAC
Cisco IAC
Cisco Unified Communications
Cisco Unified Communications
VMware vCloud Director
VMware vCloud Director
Suggested answer: C, D
asked 23/09/2024
Md Hossain
39 questions

Question 5

Report Export Collapse

What are three requirements of the Vblock System test plan? (Choose three.)

All tests identified in the test plan must be executed.
All tests identified in the test plan must be executed.
Observed results must be documented by a VCE certified resource.
Observed results must be documented by a VCE certified resource.
Tests are confidential and must not be performed in view of the customer.
Tests are confidential and must not be performed in view of the customer.
Once tests are completed, the customer must sign the test plan document.
Once tests are completed, the customer must sign the test plan document.
A completed test plan must be submitted to the VCE project manager.
A completed test plan must be submitted to the VCE project manager.
Suggested answer: B, D, E
asked 23/09/2024
Frau Abir Bouassida
34 questions

Question 6

Report Export Collapse

Which test is only performed on a Vblock System 320 that contains a high availability Advanced Management Pod (HA-AMP)?

Cisco blade server failure test
Cisco blade server failure test
Cisco UCS single power supply failure test
Cisco UCS single power supply failure test
Cisco Catalyst 3560 failure and recovery test
Cisco Catalyst 3560 failure and recovery test
Cisco UCS C220 failover test
Cisco UCS C220 failover test
Suggested answer: D
asked 23/09/2024
Sankalp Wadiwa
34 questions

Question 7

Report Export Collapse

Your manager asks you to configure an external Syslog on VMware ESXi hosts.

In which two ways would the Syslog be configured? (Choose two.)

using the vSphere client
using the vSphere client
using the esxcli system syslog command
using the esxcli system syslog command
using VMware Update Manager
using VMware Update Manager
using the VMware SQL database
using the VMware SQL database
Suggested answer: A, B
asked 23/09/2024
Premier Lane
36 questions

Question 8

Report Export Collapse

When performing hardware maintenance on a Cisco UCS B-Series blade, which GUI parameter should be selected before removing the blade out of the chassis?

Remove
Remove
Re-acknowledge
Re-acknowledge
Decommission
Decommission
Diagnostic Interrupt
Diagnostic Interrupt
Suggested answer: C
asked 23/09/2024
NAKAYAMA HIROYUKI
33 questions

Question 9

Report Export Collapse

A customer notices a failed drive error for a Vblock System 320 storage array on an EMC Unisphere screen.

Which logs must be collected and sent to VCE support to confirm that the drive has failed?

SPcollects
SPcollects
NAR files
NAR files
symapi.log
symapi.log
EMC Grab
EMC Grab
Suggested answer: A
asked 23/09/2024
Tu Nguyen
40 questions

Question 10

Report Export Collapse

Which Cisco management software is required to setup EMC e-mail home for Cisco MDS switches?

Cisco Data Center Network Manager (Cisco DCNM-SAN)
Cisco Data Center Network Manager (Cisco DCNM-SAN)
Cisco Unified Computing System Manager (Cisco UCSM)
Cisco Unified Computing System Manager (Cisco UCSM)
Cisco Smart Call Home (Cisco SCH)
Cisco Smart Call Home (Cisco SCH)
Cisco Terminal Access Controller Access Control System (Cisco TACACS)
Cisco Terminal Access Controller Access Control System (Cisco TACACS)
Suggested answer: A
asked 23/09/2024
Tyrika Warren
39 questions
Total 128 questions
Go to page: of 13

Related questions