ExamGecko
Home Home / DELL / D-PST-MN-A-24

DELL D-PST-MN-A-24 Practice Test - Questions Answers

Question list
Search
Search

Which LED combination shows a connected and working node?

A.
power LED: blinking green fault LED: blue
A.
power LED: blinking green fault LED: blue
Answers
B.
power LED: blinking green fault LED: off
B.
power LED: blinking green fault LED: off
Answers
C.
power LED: steady green fault LED: off
C.
power LED: steady green fault LED: off
Answers
D.
power LED: steady green fault LED: amber
D.
power LED: steady green fault LED: amber
Answers
Suggested answer: C

Explanation:

The LED combination that shows a connected and working node is power LED: steady green fault LED: off.

The power LED on a Dell EMC PowerStore node indicates the power status of the node.

A steady green power LED typically signifies that the node is powered on and operating normally1.

The absence of the fault LED being lit (fault LED: off) indicates that there are no current faults detected with the node1.

This combination of a steady green power LED and no fault LED is the normal operating state for a node and suggests that it is connected and functioning properly1.

For more detailed information on the LED states and what they represent, you can refer to the Dell PowerStore Hardware Information Guide or the Dell Support Knowledge Base1.

What is the reason for the best practice of leaving 2 Us of space at the bottom of the rack when racking Dell EMC PowerStore systems?

A.
Provide cooling air intake
A.
Provide cooling air intake
Answers
B.
Leave room for serviceability
B.
Leave room for serviceability
Answers
C.
Leave clearance for wheel roll
C.
Leave clearance for wheel roll
Answers
D.
Provide better rack stability
D.
Provide better rack stability
Answers
Suggested answer: B

Explanation:

The reason for the best practice of leaving 2 Us of space at the bottom of the rack when racking Dell EMC PowerStore systems is to leave room for serviceability.

When installing a Dell EMC PowerStore system, it is recommended to leave 2 Us of space at the bottom of the rack.

This space is not for cooling, wheel clearance, or stability, but rather to ensure that there is enough room for service activities1.

Serviceability involves the ability to access and maintain hardware components easily. The additional space allows for better maneuverability and access to the system for maintenance and repairs.

Following this best practice helps in preventing potential issues that might arise from cramped spaces, which can make it difficult to perform necessary service tasks1.

For more detailed information on installation best practices, refer to the Dell EMC PowerStore Quick Start Guide or the Best Practices Guide21.

When planning for a Dell EMC PowerStore T implementation, what is the minimum number of IP addresses required for the storage network?

A.
3
A.
3
Answers
B.
1
B.
1
Answers
C.
2
C.
2
Answers
D.
4
D.
4
Answers
Suggested answer: C

Explanation:

When planning for a Dell EMC PowerStore T implementation, the minimum number of IP addresses required for the storage network is two. This is because each PowerStore T appliance requires a minimum of one IP address per node for the storage network. Since the PowerStore T model typically comes with two nodes (Node A and Node B), you will need at least two IP addresses---one for each node1.

It's important to note that while two IP addresses are the minimum requirement, having additional IP addresses can be beneficial for optimization purposes. For example, the PowerStore 3000X, 5000X, 7000X, and 9000X models recommend having six IP addresses minimum per appliance for the storage network, with eight being recommended for optimization2.

In summary, for a basic PowerStore T setup, two IP addresses are required for the storage network to accommodate each node within the appliance. However, depending on the specific model and the scale of your implementation, more IP addresses may be recommended to ensure optimal performance and management of the storage network.

How is a defective embedded module displayed in Dell EMC PowerStore Manager?

A.
Blue with a faulted state
A.
Blue with a faulted state
Answers
B.
Orange with a faulted state
B.
Orange with a faulted state
Answers
C.
Orange with an empty state
C.
Orange with an empty state
Answers
D.
Blue with an empty state
D.
Blue with an empty state
Answers
Suggested answer: B

Explanation:

In Dell EMC PowerStore Manager, a defective embedded module is displayed as orange with a faulted state. This color coding is used to indicate that there is a fault with the embedded module. The PowerStore Manager provides a visual representation of the system's health and status, and the color orange is typically associated with a warning or an issue that needs attention.

The procedure for identifying and replacing a faulted embedded module involves using the PowerStore Manager to locate the faulted component. Once identified, the module displays an orange LED to indicate its faulted state. This is part of the system's design to help administrators quickly and easily identify components that require attention1.

For detailed instructions on replacing a faulted embedded module or understanding the LED states for troubleshooting, you can refer to the PowerStore documentation provided by Dell, which includes comprehensive guides on handling such scenarios2.

What describes Dell EMC PowerStore X front-end cabling?

A.
Uses internal VMware virtual switching and does not require a management network
A.
Uses internal VMware virtual switching and does not require a management network
Answers
B.
Management and discovery use the same cables and connections as storage
B.
Management and discovery use the same cables and connections as storage
Answers
C.
Storage and management use the same LACP bonded cable connection
C.
Storage and management use the same LACP bonded cable connection
Answers
D.
Uses VLTi data switch interconnectivity to support vMotion networks
D.
Uses VLTi data switch interconnectivity to support vMotion networks
Answers
Suggested answer: B

Explanation:

The Dell EMC PowerStore X series supports Ethernet connectivity through ports on the embedded module, and on optional I/O modules1. This design allows for management and discovery to use the same cables and connections as storage. The PowerStore X models support front-end NVMe connectivity with NVMe over Fibre Channel and NVMe over TCP, providing a complete end-to-end NVMe solution2.

For the PowerStore X, the management network is integrated with the storage network, which simplifies the cabling requirements and reduces the number of separate networks that need to be maintained. This integration is particularly beneficial in VMware environments where the PowerStore X can leverage internal VMware virtual switching, which further streamlines the network infrastructure1.

In summary, the front-end cabling of the Dell EMC PowerStore X is designed to consolidate management and storage networking, which simplifies the overall network design and reduces the complexity of cable management. This approach is aligned with best practices for storage connectivity and ensures efficient use of network resources3.

Which component is an FRU?

A.
DIMMs
A.
DIMMs
Answers
B.
Embedded IO Module
B.
Embedded IO Module
Answers
C.
Nodes
C.
Nodes
Answers
D.
Battery Backup Unit
D.
Battery Backup Unit
Answers
Suggested answer: D

Explanation:

A Field Replaceable Unit (FRU) is a component that can be replaced by the user or technician without having to send the entire product or system to a repair facility. Dell's Customer Replaceable Unit (CRU) program allows customers to replace designated hardware components, which are typically considered as FRUs1.

In the context of Dell PowerStore Maintenance, the Battery Backup Unit (BBU) is considered an FRU because it is designed to be easily replaced in the field. The BBU is critical for maintaining power to the system in the event of a power failure, ensuring that data is not lost and the system can be shut down gracefully.

The other components listed, such as DIMMs, Embedded IO Modules, and Nodes, may not be as easily replaceable by the customer or may require more technical expertise or special tools. Therefore, they are not typically classified as FRUs within the Dell PowerStore ecosystem.

For detailed procedures on replacing the BBU or any other FRU components, it is recommended to refer to the official Dell PowerStore Maintenance documents and follow the guidelines provided for safe and effective replacement. This ensures that the system integrity is maintained and any warranty or support agreements remain valid.

In which step of the ICW can the configuration details be exported?

A.
License Configuration
A.
License Configuration
Answers
B.
Support Assist
B.
Support Assist
Answers
C.
Cluster Configuration
C.
Cluster Configuration
Answers
D.
Cluster Details
D.
Cluster Details
Answers
Suggested answer: C

Explanation:

The configuration details can be exported during the Cluster Configuration step of the Initial Configuration Wizard (ICW) for Dell PowerStore. This step allows the user to review the chosen configuration information, validate the configuration, and initiate the cluster creation. It is at this point that the option to export the configuration details is provided1.

For a detailed guide on how to navigate the ICW and export configuration details, users should refer to the official Dell PowerStore Manager Overview documentation or the PowerStore Info Hub, which includes product documentation and videos that assist with PowerStore deployment and maintenance12. It is important to follow the official documentation to ensure that the process is carried out correctly and to maintain system integrity and compliance with warranty and support agreements.

What does the command 'svc_journalctl -f -g 'st_io_monitor''do?

A.
Deletes all logs before the specified error
A.
Deletes all logs before the specified error
Answers
B.
Rotates the log based on the specified error
B.
Rotates the log based on the specified error
Answers
C.
Ignores log messages from the specified error and re-occurring errors
C.
Ignores log messages from the specified error and re-occurring errors
Answers
D.
Retrieves log messages from the specified error and watches for re-occurrence
D.
Retrieves log messages from the specified error and watches for re-occurrence
Answers
Suggested answer: D

Explanation:

The command svc_journalctl -f -g 'st_io_monitor' is used within the Dell PowerStore environment to retrieve log messages that are associated with the specified error, in this case, ''st_io_monitor'', and to monitor for their re-occurrence. The -f flag is typically used to follow the log, meaning it will continue to output new log messages as they are appended to the journal. The -g flag is used to filter the log output based on a specific pattern1.

This command is part of the suite of service scripts provided by Dell for system maintenance and troubleshooting. It enables service technicians and system administrators to view log messages from the system journal in a consistent and easy-to-read format, which is crucial for diagnosing and resolving issues1.

For more detailed information on using this command and understanding the system journal logs, users should refer to the Dell PowerStore Service Scripts Guide or contact Dell Support for technical assistance1. It's important to use these commands as per the guidelines provided in the official documentation to ensure proper system maintenance and to avoid any unintended consequences.

Refer to the exhibit.

What is indicated when the circled LED on an expansion enclosure is illuminated amber?

A.
Expansion enclosure power-on
A.
Expansion enclosure power-on
Answers
B.
Expansion enclosure faulted
B.
Expansion enclosure faulted
Answers
C.
SAS bus link down
C.
SAS bus link down
Answers
D.
SAS bus link up
D.
SAS bus link up
Answers
Suggested answer: B

Explanation:

The illuminated amber LED on an expansion enclosure typically indicates a fault. In the context of Dell PowerStore expansion enclosures, an amber light can signify various issues such as power supply problems, cooling system malfunctions, or other operational faults that may affect the enclosure's performance.

When troubleshooting, the following steps are generally taken:

Identify the specific LED that is illuminated amber using the hardware documentation.

Consult the Dell PowerStore Hardware Guide to determine the exact nature of the fault indicated by the amber LED.

Follow the recommended actions provided in the guide, which may include checking power connections, ensuring proper airflow, or other hardware checks.

If the issue persists, contact Dell Support for further assistance, providing them with the details of the fault LED and any other relevant information observed.

It's important to address any faults indicated by an amber LED promptly to maintain the integrity and reliability of the storage system. The Dell PowerStore documentation provides comprehensive information on LED indicators and troubleshooting steps to help resolve such issues effectively.

What is the default log collection schedule?

A.
As scheduled during install
A.
As scheduled during install
Answers
B.
Hourly
B.
Hourly
Answers
C.
Weekly
C.
Weekly
Answers
D.
Daily
D.
Daily
Answers
Suggested answer: C

Explanation:

The default log collection schedule for Dell PowerStore is set to a weekly basis. This schedule is designed to balance the need for regular monitoring with the storage and processing considerations of collecting logs. Collecting logs on a weekly basis provides a sufficient overview of the system's performance and any potential issues that may arise, without overwhelming the system administrators with too much data.

The log collection process includes gathering various logs that may be required for troubleshooting PowerStore issues, such as Support Materials, Performance Metrics Archives, Dump Files, and others. The process can be initiated through the PowerStore Manager user interface or using the CLI in an SSH session1.

For more detailed information on log collection schedules and procedures, administrators should refer to the official Dell PowerStore documentation, which provides comprehensive instructions on how to generate, collect, and manage logs for effective system maintenance and troubleshooting1.

Total 61 questions
Go to page: of 7