ExamGecko
Home Home / Network Appliance / NS0-162

Network Appliance NS0-162 Practice Test - Questions Answers

Question list
Search
Search

List of questions

Search

Related questions











Exhibit.

You have a 2-node NetApp FAS2750 ONTAP cluster. You create a new 20-GB LUN In a new 100-GB volume and write 10 GB of data to the LUN. No storage efficiencies are enabled for the volume or aggregate.

Referring to the exhibit, which two statements are true? (Choose two.)

A.
ONTAP reports that the volume Is using 10 GB of Its containing aggregate.
A.
ONTAP reports that the volume Is using 10 GB of Its containing aggregate.
Answers
B.
ONTAP reports the volume as 20% full.
B.
ONTAP reports the volume as 20% full.
Answers
C.
ONTAP reports that the volume Is using 100 GB of its containing aggregate.
C.
ONTAP reports that the volume Is using 100 GB of its containing aggregate.
Answers
D.
ONTAP reports the volume as 10% full.
D.
ONTAP reports the volume as 10% full.
Answers
Suggested answer: A, D

Exhibit.

You recently added a new ESXi host to your VMware vSphere cluster. However, you cannot mount any of the existing NFS datastores to the host. Referring to the exhibit, which action solves the problem?

A.
Add NFSv4 to the access protocols.
A.
Add NFSv4 to the access protocols.
Answers
B.
Enable Kerberos in the export policy.
B.
Enable Kerberos in the export policy.
Answers
C.
Add SMB/CIFS to the access protocols.
C.
Add SMB/CIFS to the access protocols.
Answers
D.
Add HOST 3's IP address to the NFS export policy.
D.
Add HOST 3's IP address to the NFS export policy.
Answers
Suggested answer: D

You attempt to create an SVM for CIFS access only.

In this scenario, which three actions must be performed to Join the existing Active Directory?

(Choose three.)

A.
Create DNS entries.
A.
Create DNS entries.
Answers
B.
Create a data LIF.
B.
Create a data LIF.
Answers
C.
Create export policies.
C.
Create export policies.
Answers
D.
Create NTP entries.
D.
Create NTP entries.
Answers
E.
Create a cluster LIF.
E.
Create a cluster LIF.
Answers
Suggested answer: A, B, D

Explanation:

Before creating an SMB server in an Active Domain controller, you must ensure that the cluster time and the time on the domain controllers of the domain to which the SMB server will belong matches to within five minutes. https:// docs.netapp.com/ontap-9/index.jsp?topic=%2Fcom.netapp.doc.powcifs-cg%2FGUID-5AE3CADE-5EF1-403B-A664-2DEA9F13B0C8.html

Exhibit.

Referring to the exhibit, what would cause a customer to have an Issue with SVM eplc_fcp when mapping a namespace to a host?

A.
FC has not been licensed on the cluster.
A.
FC has not been licensed on the cluster.
Answers
B.
NVMe Is not configured for the SVM.
B.
NVMe Is not configured for the SVM.
Answers
C.
FC switch zoning has not been done correctly.
C.
FC switch zoning has not been done correctly.
Answers
D.
NVMe is not licensed on the cluster.
D.
NVMe is not licensed on the cluster.
Answers
Suggested answer: B

A user wants existing data in a FlexVol created in ONTAP 9.1 to be placed into a FlexGroup volume with ONTAP 9.8. In this scenario, which two statements are true? (Choose two.)

A.
Use XCP to copy data from a FlexVol to a FlexGroup.
A.
Use XCP to copy data from a FlexVol to a FlexGroup.
Answers
B.
Use SnapMirror to replicate data from FlexVol to FlexGroup.
B.
Use SnapMirror to replicate data from FlexVol to FlexGroup.
Answers
C.
You can convert the FlexVol volume to a FlexGroup volume.
C.
You can convert the FlexVol volume to a FlexGroup volume.
Answers
D.
A FlexVol to FlexGroup conversion is not supported.
D.
A FlexVol to FlexGroup conversion is not supported.
Answers
Suggested answer: B, C

Explanation:

Starting with ONTAP 9.7, you can perform an in-place conversion of a FlexVol volume to a FlexGroup volume without requiring a data copy or additional disk space. Starting with ONTAP 9.7, you can convert standalone FlexVol volumes or

FlexVol volumes that are in a SnapMirror relationship to FlexGroup volumes.

Reference: https://docs.netapp.com/ontap-9/topic/com.netapp.doc.pow-fg-mgmt/GUID-A4353B0EC0F7-4C0D-9E72-2989543FEC97.html

Which three protocols are supported by NetApp ONTAP Select? (Choose three.)

A.
NFS
A.
NFS
Answers
B.
SCSI
B.
SCSI
Answers
C.
NVMe
C.
NVMe
Answers
D.
FCP
D.
FCP
Answers
E.
CIFS
E.
CIFS
Answers
Suggested answer: A, B, E

Explanation:

Reference: https://docs.netapp.com/us-en/ontap-select/pdfs/sidebar/Deep_dive.pdf (35)

You have a remote FlexCache storage device that is running on ONTAP Select 9.8 software. The cache origin volume Is on an FAS8700 that is running ONTAP 9.8 software. The WAN connection dropped, and the FlexCache volume is in disconnected mode.

In this scenario, which LIFs would you ping to troubleshoot the disconnect?

A.
management
A.
management
Answers
B.
Intercluster
B.
Intercluster
Answers
C.
data
C.
data
Answers
D.
cluster
D.
cluster
Answers
Suggested answer: D

Explanation:

https://docs.netapp.com/ontap-9/topic/com.netapp.doc.pow-fc-mgmt/GUID-AE9CC59E-BE3B-4185-B018-E3F089CB53B0.html?cp=17_0_2

All SMB users are reporting that their network share performance Is slow on a new NetApp FAS500f HA pair. You determine that the users have converged network adapters (CNAs) with flow control enabled and no option to disable.

In this scenario, which two flow control settings are recommended on the NetApp ONTAP physical ports? (Choose two.)

A.
Disable flow control end-to-end on data network ports.
A.
Disable flow control end-to-end on data network ports.
Answers
B.
Enable flow control end-to-end on cluster network ports.
B.
Enable flow control end-to-end on cluster network ports.
Answers
C.
Enable flow control end-to-end on data network ports.
C.
Enable flow control end-to-end on data network ports.
Answers
D.
Disable flow control end-to-end on cluster network ports.
D.
Disable flow control end-to-end on cluster network ports.
Answers
Suggested answer: C, D

Explanation:

https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/What_are_the_flow_control_best_practices_for_Ethernet%3F#Clustered_Data_ONTAP_.2F_ONTAP_9_Flow_control_recommendations:

Disable flow control on cluster network ports in the Data ONTAP cluster. Flowcontrol on the remaining network ports (the ports that provide data, management, and intercluster connectivity) should be configured to match the settings within the rest of your environment.

You want to prepare your ONTAP cluster and your ESXI cluster to connect NFS datastores over a 10- GbE network using Jumbo frames. In this scenario, which three configurations would accomplish this task? (Choose three.)

A.
Enable jumbo frames with an MTU of 9000 for your ESXi hosts.
A.
Enable jumbo frames with an MTU of 9000 for your ESXi hosts.
Answers
B.
Enable jumbo frames with an MTU of 9216 for your switches.
B.
Enable jumbo frames with an MTU of 9216 for your switches.
Answers
C.
Enable Jumbo frames with an MTU of 1500 for your ESXI hosts.
C.
Enable Jumbo frames with an MTU of 1500 for your ESXI hosts.
Answers
D.
Enable Jumbo frames with an MTU of 1500 for your ONTAP cluster.
D.
Enable Jumbo frames with an MTU of 1500 for your ONTAP cluster.
Answers
E.
Enable Jumbo frames with an MTU of 9000 for your ONTAP cluster.
E.
Enable Jumbo frames with an MTU of 9000 for your ONTAP cluster.
Answers
Suggested answer: A, B, E

Explanation:

Reference: https://library.netapp.com/ecm/ecm_download_file/ECMLP2496234 (9)

You ate the administrator of an ONTAP 9.8 cluster. You have configured an hourly snapshot schedule for all NAS volumes. One of your users accidentally deleted an Important spreadsheet file on an SMB share. The file needs to be restored as quickly as possible by the Windows user.

Which statement is correct in this scenario?

A.
On the cluster CLI, execute the volume clone create command with the -parent-snapshot option set to the latest Snapshot copy and share the cloned volume as an SMB share, then copy the file back.
A.
On the cluster CLI, execute the volume clone create command with the -parent-snapshot option set to the latest Snapshot copy and share the cloned volume as an SMB share, then copy the file back.
Answers
B.
On the cluster CLI, execute the volume snapshot restore-file command with the options to select the Snapshot, path, and restore-path
B.
On the cluster CLI, execute the volume snapshot restore-file command with the options to select the Snapshot, path, and restore-path
Answers
C.
In ONTAP System Manager, navigate to the volume where the share resides, click on snapshot copies and restore the latest Snapshot copy.
C.
In ONTAP System Manager, navigate to the volume where the share resides, click on snapshot copies and restore the latest Snapshot copy.
Answers
D.
In Windows Explorer, right-click on the SMB share where the file was deleted, go to previous versions select the file and copy It to the original location.
D.
In Windows Explorer, right-click on the SMB share where the file was deleted, go to previous versions select the file and copy It to the original location.
Answers
Suggested answer: D

Explanation:

Reference: https://docs.microsoft.com/en-us/azure/azure-netapp-files/azure-netapp-files-managesnapshots

Total 89 questions
Go to page: of 9