NS0-521: Implementation Engineer - SAN ONTAP
Network Appliance
Related questions
When using tagged VLANs on Cisco Nexus switches for NVMe over TCP, which two changes must be made to enable jumbo frames? (Choose two.)
Explanation:
For enabling jumbo frames on Cisco Nexus switches for NVMe over TCP with tagged VLANs, the following changes are required:
Modify the Cisco Nexus switches to use an MTU of 9216: Setting the MTU to 9216 ensures that the network can handle jumbo frames, reducing the number of packets needed for large data transfers and thus improving performance.
Modify the appropriate broadcast domain in NetApp ONTAP software to use an MTU of 9216: This setting must match the network configuration to ensure end-to-end support for jumbo frames, which is essential for optimizing performance in NVMe over TCP environments.
For additional information, refer to:
NetApp Documentation on NVMe over TCP
Cisco Documentation on Jumbo Frames
A customer Is deploying a new 8-node NetApp ONTAP cluster for their SAN workloads using FCP, NVMe/FC, and NVMe/TCP.
In this scenario, which statement is true?
A customer has created an SVM for their SAN workloads. They now want to configure the SVM to use NVMe/FC. Which two steps are needed to accomplish this task? (Choose two.)
Explanation:
To configure an SVM to use NVMe/FC, the following steps are necessary:
Add the FC protocol: This step involves enabling the Fibre Channel protocol on the SVM, which is required to support NVMe over Fibre Channel.
Create an NVMe/FC LIF: Logical Interfaces (LIFs) must be created to handle NVMe traffic over the Fibre Channel network. These LIFs enable the NVMe namespace access to the host systems.
These steps ensure that the SVM is correctly set up to use NVMe/FC, allowing for efficient and high-performance access to NVMe storage.
For more information, refer to:
NetApp NVMe/FC Configuration
A storage administrator has just completed an ISCSI implementation in a customer environment running VMware and needs to validate that the entire network path supports jumbo frames.
Which action should be taken?
Explanation:
To validate that the entire network path supports jumbo frames after an iSCSI implementation, you should perform a ping test from the host with fragmentation. This involves using the ping command with specific options to test jumbo frame support:
ping -M do -s 8972 <target_IP>
In this command:
-M do ensures the packets are not fragmented.
-s 8972 sets the packet size to 8972 bytes (9000 bytes MTU minus 28 bytes for the ICMP header).
By confirming that the large packets are successfully transmitted without fragmentation, you can validate that the network path, including switches and adapters, supports jumbo frames.
For more details, you can check:
NetApp Documentation - iSCSI Configuration and Best Practices (NetApp) (NetApp).
When using FCP, what is the minimum number of FC switches needed to redundantly attach three ESXi hosts?
A site survey has been conducted for an installation of a switchless HA pair with two NetApp DS224C shelves in the customer's already populated rack.
Which of the following two need to be verified to ensure a successful deployment? (Choose two.)
Explanation:
For a successful deployment of a switchless HA pair with two NetApp DS224C shelves in an already populated rack, it is crucial to verify:
Rack units: Ensure that there are enough rack units available to accommodate the new shelves and any associated equipment. Proper planning of space in the rack is essential for a neat and functional setup.
Power connections: Verify that there are sufficient and appropriately rated power connections available. Ensuring proper power distribution and redundancy is critical for the reliability and uptime of the storage system.
For more details, refer to:
NetApp Documentation on Rack Installation
NetApp Community Discussion on Power Connections
A storage engineer in SAN environment needs to Identify FC ports using the company-wide naming policy. Which command will accomplish this task?
An administrator is planning a SAN implementation and needs to validate that the ESXI host and NetApp ONTAP software releases are supported.
Which tool is used to accomplish this?
A storage administrator has a NetApp AFF SAN cluster in a multitenant environment. Another user has requested access to perform only replication within a specific SVM to another cluster.
Which default role would be used in this scenario?
Explanation:
In a multitenant environment where a user needs access only to perform replication within a specific SVM to another cluster, the default role vsadmin-backup is appropriate. This role provides the necessary permissions to manage backup and replication tasks without granting broader administrative rights.
For more details, see:
NetApp Documentation on User Roles
NetApp Community Discussion on Roles
An administrator is configuring ISCSI on an SVM and requires that all network traffic Is encrypted. What must be done to satisfy this requirement?
Explanation:
To ensure that all network traffic is encrypted for iSCSI on an SVM, configuring IPsec is required. IPsec (Internet Protocol Security) provides end-to-end encryption for IP traffic, ensuring that data transmitted over the network is secure.
For more details, refer to:
NetApp Documentation on Configuring IPsec
Question