ExamGecko
Home Home / Network Appliance / NS0-521

Network Appliance NS0-521 Practice Test - Questions Answers

Question list
Search
Search

List of questions

Search

Related questions











A customer Is setting up a two-node cluster to serve (SCSI LUNs. How many interfaces should be created?

A.
One iSCSI LIF per node
A.
One iSCSI LIF per node
Answers
B.
One ISCSI LIF per SVM
B.
One ISCSI LIF per SVM
Answers
C.
Two iSCSI LIFs per node
C.
Two iSCSI LIFs per node
Answers
D.
Two ISCSI LIFs per SVM
D.
Two ISCSI LIFs per SVM
Answers
Suggested answer: C

Explanation:

For a two-node cluster serving iSCSI LUNs, it is recommended to create two iSCSI LIFs per node. This configuration provides redundancy and load balancing, ensuring that each node can handle failover scenarios effectively and maintain high availability for the iSCSI connections.

For more details, see:

NetApp Documentation on iSCSI LIF Configuration

An administrator upgraded their NetApp ONTAP software from release 9.10.1 to 9.13.1 on a NetApp All SAN Array (ASA) cluster and is creating a new iSCSI SVM.

Which automatic feature can be used with iSCSI?

A.
LIF failover
A.
LIF failover
Answers
B.
LUN mapping
B.
LUN mapping
Answers
C.
CHAP authentication
C.
CHAP authentication
Answers
D.
igroup creation
D.
igroup creation
Answers
Suggested answer: A

Explanation:

In NetApp ONTAP 9.13.1, one of the automatic features that can be used with iSCSI is LIF failover. This feature ensures that in the event of a network failure or a node issue, the Logical Interface (LIF) will automatically fail over to another available port, maintaining connectivity and minimizing disruption to iSCSI traffic.

For more information, refer to:

NetApp ONTAP 9.13.1 Features

An SVM is created for FCP traffic. LUNs must be created to share with ESXi hosts for datastores. Which two items must be configured after the LUN is created, for this to happen? (Choose two.)

A.
Create an igroup with the ESXi hosts' WWPNs.
A.
Create an igroup with the ESXi hosts' WWPNs.
Answers
B.
Create an igroup with the ESXi hosts' WWNNs.
B.
Create an igroup with the ESXi hosts' WWNNs.
Answers
C.
Configure CHAP authentication.
C.
Configure CHAP authentication.
Answers
D.
Map the LUNs to the igroup.
D.
Map the LUNs to the igroup.
Answers
Suggested answer: A, D

Explanation:

For configuring LUNs to share with ESXi hosts for datastores in an SVM created for FCP traffic, the following steps are necessary after creating the LUN:

Create an igroup with the ESXi hosts' WWPNs: This step involves defining an initiator group that includes the WWPNs of the ESXi hosts that need access to the LUN.

Map the LUNs to the igroup: This step assigns the LUN to the created igroup, allowing the ESXi hosts to access the LUN.

For further details, refer to:

NetApp Documentation on LUN and igroup Configuration

An administrator needs to ensure that Snapshot copies of database files across multiple FCP LUNs are taken at the same point in time.

Which two configurations enable the administrator to achieve this? (Choose two.)

A.
Create each LUN within the same FlexVol volume.
A.
Create each LUN within the same FlexVol volume.
Answers
B.
Create a consistency group that uses FlexGroup volumes.
B.
Create a consistency group that uses FlexGroup volumes.
Answers
C.
Create a consistency group that uses FlexVol volumes.
C.
Create a consistency group that uses FlexVol volumes.
Answers
D.
Create each LUN within the same FlexGroup volume.
D.
Create each LUN within the same FlexGroup volume.
Answers
Suggested answer: C, D

Explanation:

To ensure that Snapshot copies of database files across multiple FCP LUNs are taken at the same point in time, the following configurations can be used:

Create a consistency group that uses FlexVol volumes: This setup ensures that snapshots of all volumes in the consistency group are taken simultaneously.

Create each LUN within the same FlexGroup volume: This configuration allows for a unified snapshot across multiple LUNs within the FlexGroup, ensuring data consistency.

For more details, see:

NetApp Documentation on Consistency Groups

NetApp FlexGroup Overview

Which two NetApp features provide synchronous data replication between two sites for SAN workloads with automatic failover in case of a site disaster? (Choose two.)

A.
SnapMirror active sync
A.
SnapMirror active sync
Answers
B.
SnapMirror SVM
B.
SnapMirror SVM
Answers
C.
SnapMirror Synchronous
C.
SnapMirror Synchronous
Answers
D.
MetroCluster IP
D.
MetroCluster IP
Answers
Suggested answer: C, D

Explanation:

For synchronous data replication between two sites with automatic failover in case of a site disaster for SAN workloads, the two NetApp features that provide these capabilities are SnapMirror Synchronous and MetroCluster IP.

SnapMirror Synchronous: This feature provides volume-granular, synchronous replication with zero RPO (Recovery Point Objective), ensuring that data is mirrored in real-time to a secondary site. This setup supports automatic failover, maintaining data availability even during site failures

MetroCluster IP: This solution provides synchronous replication and combines high availability and disaster recovery capabilities. MetroCluster IP uses IP networking to extend the distance over which replication can occur and supports automatic failover and failback, making it suitable for critical SAN workloads

An administrator runs the vserver nvme namespace convert-from-iun command on a NetApp ASA cluster to increase host performance.

What is modified by the convert command?

A.
FlexVol
A.
FlexVol
Answers
B.
FlexClone
B.
FlexClone
Answers
C.
LUN clone
C.
LUN clone
Answers
D.
Metadata
D.
Metadata
Answers
Suggested answer: D

Explanation:

The vserver nvme namespace convert-from-lun command in a NetApp ASA cluster is used to convert a LUN to an NVMe namespace to increase host performance. This process involves modifying the metadata of the storage object to make it compatible with the NVMe protocol, allowing for faster access and reduced latency

A healthcare customer wants to Implement an FC SAN solution consisting of a NetApp ONTAP system, Broadcom switches, and servers.

Which tool contains detailed blueprints and implementation references that can be used to design this solution?

A.
NetApp Fusion
A.
NetApp Fusion
Answers
B.
NetApp Verified Architecture
B.
NetApp Verified Architecture
Answers
C.
NetApp Active IQ Config Advisor
C.
NetApp Active IQ Config Advisor
Answers
D.
NetApp Active IQ Unified Manager
D.
NetApp Active IQ Unified Manager
Answers
Suggested answer: B

Explanation:

The correct tool for designing an FC SAN solution consisting of a NetApp ONTAP system, Broadcom switches, and servers is the 'NetApp Verified Architecture' (NVA). The NetApp Verified Architecture provides comprehensive blueprints and detailed implementation references. These blueprints are thoroughly tested, prescriptive in nature, and designed to minimize deployment risks and accelerate time to market. They are specifically designed to help ensure that the architecture meets the high standards required for enterprise environments.

NVA documents include design guides, best practices, and detailed configuration steps, making them invaluable for planning and deploying complex solutions like the one described.

For more information, you can refer to the official NetApp documentation on NetApp Verified Architectures:

NetApp Verified Architecture Program Summary

NetApp Verified Architecture Overview

These resources provide detailed insights into the architecture, including technology requirements, deployment procedures, and additional references for further reading.

An administrator is setting up a NetApp ONTAP AFF system for both NVMe/TCP and iSCSI. Which task is required for SAN configuration?

A.
Configure CHAP authentication.
A.
Configure CHAP authentication.
Answers
B.
Configure DH-HMAC-CHAP authentication.
B.
Configure DH-HMAC-CHAP authentication.
Answers
C.
Configure LIFs.
C.
Configure LIFs.
Answers
D.
Configure IPsec.
D.
Configure IPsec.
Answers
Suggested answer: C

Explanation:

When setting up a NetApp ONTAP AFF system for both NVMe/TCP and iSCSI, a critical task required for SAN configuration is to configure Logical Interfaces (LIFs). LIFs are necessary for network connectivity and are used by both NVMe/TCP and iSCSI protocols to communicate between the storage system and the host.

The configuration of LIFs involves creating and managing these interfaces to ensure they are correctly mapped and available for use by the respective protocols. This step is essential for the SAN setup to function properly.

For more detailed steps on configuring LIFs, you can refer to NetApp's documentation:

How to Configure NVMe/TCP with ONTAP (NetApp Community).

SAN Configuration with ONTAP (NetApp).

An administrator has a NetApp AFF cluster with two SVMs serving LUNs. SnapMirror active sync is configured, and a disaster recovery test is planned over the weekend.

Which NetApp ONTAP command will show the status of this test?

A.
snapmirror failover show
A.
snapmirror failover show
Answers
B.
network interface failover-groups show
B.
network interface failover-groups show
Answers
C.
storage failover hwassist show
C.
storage failover hwassist show
Answers
D.
snapnirror config-replication status show
D.
snapnirror config-replication status show
Answers
Suggested answer: A

Explanation:

To check the status of a SnapMirror active sync disaster recovery test on a NetApp ONTAP cluster, you would use the command snapmirror failover show. This command provides the necessary details about the failover status, helping administrators verify if the disaster recovery test is proceeding as expected. It displays the status of the failover groups and their readiness, which is essential for confirming the effectiveness of the disaster recovery setup.

For more detailed information on SnapMirror commands and their usage, refer to:

NetApp Documentation - SnapMirror Commands (NetApp Community) (NetApp Community).

What configuration must be applied for NVMe/FC?

A.
Create multiple initiator zones and multiple target zones.
A.
Create multiple initiator zones and multiple target zones.
Answers
B.
Configure igroup and IQN mapping.
B.
Configure igroup and IQN mapping.
Answers
C.
Enable NPV on all fabric switches.
C.
Enable NPV on all fabric switches.
Answers
D.
Enable NPIV on all fabric switches.
D.
Enable NPIV on all fabric switches.
Answers
Suggested answer: D

Explanation:

When configuring NVMe/FC (NVMe over Fibre Channel), it is necessary to enable N_Port ID Virtualization (NPIV) on all fabric switches. NPIV allows multiple Fibre Channel initiators to share a single physical Fibre Channel port, which is crucial for NVMe/FC environments where efficient utilization of available ports is needed.

NPIV support enables the creation of virtual ports, which can significantly optimize the configuration and management of Fibre Channel fabrics, thus supporting NVMe/FC operations.

For further details, you can refer to:

NetApp Community - NVMe/FC Configuration (NetApp Community).

NetApp Documentation - NVMe Overview (NetApp).

Total 65 questions
Go to page: of 7