Question 1

Report Export Collapse

You are sizing a FlexPod Datacenter solution for multitenancy use.

What are two important platform scaling considerations in this scenario? (Choose two.)

maximum NetApp ONTAP cluster limits
maximum NetApp ONTAP cluster limits
maximum NetApp ONTAP storage VM limits
maximum NetApp ONTAP storage VM limits
maximum Cisco vPC interfaces between Fabric Interconnects
maximum Cisco vPC interfaces between Fabric Interconnects
maximum Cisco L1, L2 interfaces between Fabric Interconnects
maximum Cisco L1, L2 interfaces between Fabric Interconnects
Suggested answer: A, D
asked 23/09/2024
mark anthony sampayan
34 questions

Question 2

Report Export Collapse

You are developing a FlexPod solution with a MetroCluster IP as the storage solution.

In this scenario, which two components are supported? (Choose two.)

NetApp AFF C190
NetApp AFF C190
Cisco Nexus 3524-X/XL
Cisco Nexus 3524-X/XL
Cisco Nexus 3232C
Cisco Nexus 3232C
NetApp AFF A400
NetApp AFF A400
Suggested answer: C, D
Explanation:

Reference: https://www.netapp.com/blog/flexpod-datacenter-solutions/

asked 23/09/2024
Krzychu Kn
42 questions

Question 3

Report Export Collapse

You are asked to evaluate SaaS-based monitoring solutions for your FlexPod environment. Other than being SaaS-delivered, selection criteria include full lifecycle management, environment automation, and the ability to monitor third-party storage that is salted for retirement.

In this scenario, which product satisfies the requirements?

NetApp Cloud Insights
NetApp Cloud Insights
NetApp OnCommand Insight
NetApp OnCommand Insight
Cisco UCS Manager
Cisco UCS Manager
Cisco Intersight
Cisco Intersight
Suggested answer: A
Explanation:

Reference: https://cloud.netapp.com/hubfs/WP-7302-Cloud-Insights-Monitoring-Guide.pdf

asked 23/09/2024
Tracy Sampson
34 questions

Question 4

Report Export Collapse

A customer wants to use a Cisco Nexus 93180YC-FX switch to support the FC protocol for booting from SAN without having to deploy additional Cisco 900 Series MDS switches in their FlexPod Datacenter configuration.

In this scenario, what is required for this solution?

The customer must enable the FC license on the 93180YC-FX switch
The customer must enable the FC license on the 93180YC-FX switch
The customer must deploy the 93180YC-FX switch as part of a Cisco ACI fabric
The customer must deploy the 93180YC-FX switch as part of a Cisco ACI fabric
The customer must directly connect the NetApp AFF system to the Cisco UCS Fabric InterconnectsD. The customer must add an expansion FC module to the 93180YC-FX switch
The customer must directly connect the NetApp AFF system to the Cisco UCS Fabric InterconnectsD. The customer must add an expansion FC module to the 93180YC-FX switch
Suggested answer: C
Explanation:

Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/fp_vmware_vsphere_7_0_ontap_9_7.html

asked 23/09/2024
Emily Luijten
46 questions

Question 5

Report Export Collapse

You are designing a multi-site FlexPod Datacenter solution for a customer using MetroCluster over IP. The design should include a single set of compliant switches for the environment.

Which two features are required to satisfy this requirement? (Choose two.)

support for Fibre Channel ports
support for Fibre Channel ports
support for an MTU size of 9216
support for an MTU size of 9216
support for unified switch ports
support for unified switch ports
support for QoS
support for QoS
Suggested answer: A, D
Explanation:

Reference: https://www.netapp.com/blog/flexpod-datacenter-solutions/

asked 23/09/2024
Francisli Lilles
42 questions

Question 6

Report Export Collapse

You are sizing a FlexPod Virtual Desktop solution for a customer with 500 virtual desktops in a shared Remote Desktop Services (RDS) topology.

In this scenario, which Cisco best practice should you use?

You should avoid placing more than 20 users per physical host
You should avoid placing more than 20 users per physical host
You should avoid over-committing physical CPU resources for virtual machines
You should avoid over-committing physical CPU resources for virtual machines
You should avoid changing the virtual host disk queue depth
You should avoid changing the virtual host disk queue depth
You should avoid multiple vCPUs per individual virtual machine
You should avoid multiple vCPUs per individual virtual machine
Suggested answer: B
Explanation:

Reference: https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/techpaper/View51_on_FlexPod_Design_Guide.pdf

asked 23/09/2024
Christie Clark
40 questions

Question 7

Report Export Collapse

You have a FlexPod solution that consists of a NetApp AFF A800 storage system, a Cisco MDS 9148S switch, and a Cisco UCS 6232 Fabric Interconnect. You want to upgrade NetApp ONTAP software on the AFF A800 to take advantage of a new feature.

In this scenario, which three tools would enable you to verify if the upgrade would be performed safely? (Choose three.)

NetApp Interoperability Matrix Tool
NetApp Interoperability Matrix Tool
Cisco Intersight
Cisco Intersight
Cisco Data Center Network Manager
Cisco Data Center Network Manager
Cisco UCS Hardware and Software Compatibility List
Cisco UCS Hardware and Software Compatibility List
NetApp Active IQ Upgrade Advisor
NetApp Active IQ Upgrade Advisor
Suggested answer: A, B, C
asked 23/09/2024
NEURONES TECHNOLOGIES
42 questions

Question 8

Report Export Collapse

You are designing a new FlexPod solution to use with VMware vSphere by using NFS datastores and want to ensure maximum availability by using a vPC.

In this scenario, on which Cisco component would you configure vPC interfaces?

Cisco UCS Fabric Interconnect
Cisco UCS Fabric Interconnect
Cisco MDS switches
Cisco MDS switches
Cisco Nexus switches
Cisco Nexus switches
UCS B-Series blade server
UCS B-Series blade server
Suggested answer: C
Explanation:

Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_vmware_vs_7_design.html

asked 23/09/2024
Maritza Van Der Merwe
36 questions

Question 9

Report Export Collapse

What are three requirements for all FlexPod Datacenter solutions?

(Choose three.)

two NetApp storage controllers in a high-availability (HA) pair configuration
two NetApp storage controllers in a high-availability (HA) pair configuration
a separate 100 Mbps Ethernet/1 Gbps Ethernet out-of-band management network
a separate 100 Mbps Ethernet/1 Gbps Ethernet out-of-band management network
a pair of Fabric Extenders in a redundant configuration
a pair of Fabric Extenders in a redundant configuration
two Cisco UCS 6200, 6300, or 6400 Series Fabric Interconnects in a redundant configurationE. redundant boot-from-SAN LUN paths
two Cisco UCS 6200, 6300, or 6400 Series Fabric Interconnects in a redundant configurationE. redundant boot-from-SAN LUN paths
Suggested answer: C, D
asked 23/09/2024
JAVIER MALDONADO
31 questions

Question 10

Report Export Collapse

A customer wants to deploy a FlexPod Datacenter solution in a limited amount of rack space. After planning for the networking and storage devices required for the deployment, they realize they have six rack units of space remaining. They need to install as many servers as possible in this available rack space.

In this scenario, which solution allows them to accomplish their objective?

three Cisco UCS C4200 rack servers
three Cisco UCS C4200 rack servers
four Cisco UCS B480 M blade servers
four Cisco UCS B480 M blade servers
six Cisco UCS C220 M5 rack servers
six Cisco UCS C220 M5 rack servers
eight Cisco UCS B200 M5 blade servers
eight Cisco UCS B200 M5 blade servers
Suggested answer: D
Explanation:

Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_vmware_vs_7_design.html#_Toc58868310

asked 23/09/2024
Pavol Adamcin
35 questions
Total 60 questions