What are the required settings when using terminal emulation software to connect to a Dell EMC PowerScale Gen 5 node?

A.

Transfer Rate = 57.600, Data Bits = 8, Parity = 1, Stop Bits = 0, Flow Control = Software

A.

Transfer Rate = 57.600, Data Bits = 8, Parity = 1, Stop Bits = 0, Flow Control = Software

Answers
B.

Transfer Rate = 115.200, Data Bits = 8, Parity = None, Stop Bits = 1, Flow Control = Hardware

B.

Transfer Rate = 115.200, Data Bits = 8, Parity = None, Stop Bits = 1, Flow Control = Hardware

Answers
C.

Transfer Rate = 57.600, Data Bits = 7, Parity = 1, Stop Bits = 8, Flow Control = Hardware

C.

Transfer Rate = 57.600, Data Bits = 7, Parity = 1, Stop Bits = 8, Flow Control = Hardware

Answers
D.

Transfer Rate = 115.200, Data Bits = 7, Parity = 1, Stop Bits = 1, Flow Control = Software

D.

Transfer Rate = 115.200, Data Bits = 7, Parity = 1, Stop Bits = 1, Flow Control = Software

Answers
Suggested answer: B

Explanation:

For serial console connections to a Gen 5 node, specific terminal settings are required.

Required Settings:

Transfer Rate (Baud Rate): 115,200 bps

Data Bits: 8

Parity: None

Stop Bits: 1

Flow Control: Hardware

Dell PowerScale

Reference:

Dell EMC PowerScale Hardware Installation Guide:

Serial Connection Settings:

Provides the exact settings for terminal emulation software.

Recommends these settings for successful communication.

Best Practices:

Use reliable terminal software (e.g., PuTTY).

Verify cable connections and adapter compatibility.

A platform engineer is creating a Dell PowerScale cluster that must meet SEC 17a-4f rules. Node 1 is powered on and cabled.

What action must be taken to meet the requirement?

A.

Create a cluster.

A.

Create a cluster.

Answers
B.

Reboot into SmartLock Compliance mode.

B.

Reboot into SmartLock Compliance mode.

Answers
C.

Activate the Enterprise Security mode license.

C.

Activate the Enterprise Security mode license.

Answers
D.

Call Dell Tech Support to configure the cluster manually.

D.

Call Dell Tech Support to configure the cluster manually.

Answers
Suggested answer: B

Explanation:

To meet SEC 17a-4(f) regulations, the platform engineer must reboot the node into SmartLock Compliance mode before creating the cluster.

Understanding SEC 17a-4(f) Requirements:

SEC 17a-4(f):

A regulation that requires electronic records to be stored in a non-rewriteable, non-erasable format (WORM - Write Once Read Many).

Compliance Necessity:

Financial institutions must comply to ensure data integrity and regulatory adherence.

Dell PowerScale SmartLock Compliance Mode:

SmartLock Compliance Mode:

Provides WORM storage capabilities that meet SEC 17a-4(f) requirements.

Once enabled, it cannot be disabled, ensuring data remains immutable.

Activation Process:

Nodes must be booted into Compliance mode before cluster creation.

Requires selecting the Compliance mode boot option during node initialization.

Required Action:

Reboot into SmartLock Compliance Mode:

Power on Node 1 and access the boot menu.

Select the option to boot into SmartLock Compliance mode.

Proceed with cluster creation in this mode.

Why Other Options Are Less Suitable:

Option A (Create a cluster):

Creating the cluster without first booting into Compliance mode would not meet SEC 17a-4(f) requirements.

Option C (Activate the Enterprise Security mode license):

Enterprise Security mode enhances security features but does not specifically enable WORM storage.

Option D (Call Dell Tech Support to configure the cluster manually):

While Dell Support can assist, the engineer must still reboot into Compliance mode as per procedure.

Important Considerations:

Irreversible Setting:

Once in Compliance mode, the cluster cannot revert to a standard mode.

Data Handling:

All data stored will be subject to WORM policies.

Planning:

Ensure that Compliance mode is necessary before proceeding, as it affects the entire cluster.

Dell PowerScale

Reference:

Dell EMC PowerScale OneFS SmartLock Administration Guide:

Provides detailed instructions on enabling Compliance mode.

Dell EMC PowerScale OneFS SmartLock Guide

Dell EMC PowerScale OneFS Security Configuration Guide:

Discusses regulatory compliance features.

Dell EMC PowerScale OneFS Security Guide

Knowledge Base Articles:

Article ID 000123008: 'Configuring SmartLock Compliance Mode for SEC 17a-4(f) Compliance'

Article ID 000123009: 'Steps to Enable Compliance Mode on PowerScale Clusters'

A customer wants to add SSDs to the drive sleds in a Dell PowerScale H600 node for higher storage performance. What should the platform engineer tell the customer?

A.

Cache expansion requires a Dell Professional Services engagement.

A.

Cache expansion requires a Dell Professional Services engagement.

Answers
B.

Hybrid node SSDs in identical sled locations can be used for either cache or primary storage.

B.

Hybrid node SSDs in identical sled locations can be used for either cache or primary storage.

Answers
C.

Only F series nodes can use SSDs for primary storage.

C.

Only F series nodes can use SSDs for primary storage.

Answers
D.

Each sled must have an equal number of SSDs.

D.

Each sled must have an equal number of SSDs.

Answers
Suggested answer: B

Explanation:

The platform engineer should inform the customer that hybrid node SSDs in identical sled locations can be used for either cache or primary storage.

Understanding Dell PowerScale H600 Nodes:

Hybrid Nodes:

H600 nodes are hybrid, combining HDDs for capacity and SSDs for performance.

Drive Sleds:

Nodes have sleds (drive bays) where drives are installed.

SSDs and HDDs are populated in specific sled locations.

Using SSDs for Cache or Primary Storage:

Flexibility:

SSDs in hybrid nodes can serve as either L3 cache or as a tier for primary storage.

Identical Sled Locations:

For consistency and performance optimization, SSDs should be installed in identical sled positions across all nodes in the pool.

Configuration:

Administrators can configure the usage of SSDs through SmartPools and data storage policies.

Benefits of Using SSDs for Primary Storage:

Performance Improvement:

Storing hot or frequently accessed data on SSDs enhances read/write speeds.

Data Tiering:

OneFS can automatically move data between SSDs and HDDs based on access patterns.

Why Other Options Are Less Suitable:

Option A (Cache expansion requires a Dell Professional Services engagement):

While professional services can assist, customers can add SSDs and configure caching without mandatory professional services.

Option C (Only F series nodes can use SSDs for primary storage):

Incorrect; hybrid nodes can also use SSDs for primary storage via SmartPools.

Option D (Each sled must have an equal number of SSDs):

Not strictly required; however, best practices recommend balanced configurations for performance consistency.

Best Practices:

Balanced Configuration:

Install SSDs uniformly across nodes to maintain consistent performance.

Consult Documentation:

Review hardware guides and configuration manuals for specific instructions.

Dell PowerScale

Reference:

Dell EMC PowerScale OneFS SmartPools Administration Guide:

Details on configuring SSDs for primary storage and caching.

Dell EMC PowerScale OneFS SmartPools Guide

Dell EMC PowerScale H600 Hardware Guide:

Provides information on drive sled configurations and SSD usage.

Dell EMC PowerScale H600 Hardware Guide

Knowledge Base Articles:

Article ID 000123010: 'Using SSDs in Hybrid Nodes for Primary Storage'

Article ID 000123011: 'Configuring SSDs in Dell PowerScale Hybrid Nodes'

A customer received replacement parts from Dell without prior communication.

Why did they receive the replacement parts?

A.

The cluster is configured with Secure Remote Services only.

A.

The cluster is configured with Secure Remote Services only.

Answers
B.

The cluster is enrolled in the AutoCRU program.

B.

The cluster is enrolled in the AutoCRU program.

Answers
C.

The cluster is configured with SCG.

C.

The cluster is configured with SCG.

Answers
D.

The cluster is configured with SupportAssist only.

D.

The cluster is configured with SupportAssist only.

Answers
Suggested answer: B

Explanation:

The customer received replacement parts from Dell without prior communication because the cluster is enrolled in the AutoCRU (Automatic Customer Replaceable Unit) program. The AutoCRU program is designed to streamline the parts replacement process by automatically shipping Customer Replaceable Units (CRUs) when a failure is detected, without the need for prior communication or manual intervention.

1. Understanding AutoCRU Program:

AutoCRU Program Overview:

The AutoCRU program enables Dell to automatically dispatch replacement CRUs directly to the customer when a hardware issue is detected.

It reduces downtime by eliminating the need for the customer to contact Dell Support to initiate a replacement.

Applicable for parts classified as CRUs, which customers can replace themselves.

Enrollment in AutoCRU:

Customers must opt-in to participate in the AutoCRU program.

Enrollment involves agreeing to terms and ensuring proper configuration of remote monitoring tools.

2. How AutoCRU Works with PowerScale Clusters:

Remote Monitoring:

The cluster is monitored using tools like Secure Remote Services (SRS) or Secure Connect Gateway (SCG).

These tools send alerts to Dell when hardware issues are detected.

Automatic Dispatch:

Upon detecting a failure, the system generates a service request.

The AutoCRU process initiates, and replacement parts are shipped automatically to the customer's site.

No Prior Communication Needed:

The automation eliminates the need for prior communication, expediting the replacement process.

Customers receive parts promptly, minimizing potential downtime.

3. Why Other Options Are Less Suitable:

Option A: The cluster is configured with Secure Remote Services only.

While SRS enables remote monitoring, it does not automatically dispatch parts without the AutoCRU program.

SRS requires manual intervention to create service requests unless combined with AutoCRU.

Option C: The cluster is configured with SCG.

Secure Connect Gateway (SCG) is the modern replacement for SRS.

Similar to SRS, SCG facilitates remote monitoring but does not inherently provide automatic parts dispatch without AutoCRU enrollment.

Option D: The cluster is configured with SupportAssist only.

SupportAssist provides proactive monitoring and can generate alerts.

However, automatic parts dispatch requires participation in the AutoCRU program.

4. Dell PowerScale

Reference:

Dell EMC AutoCRU Program Details:

Provides information on the benefits and enrollment process for AutoCRU.

Dell EMC AutoCRU Program

Secure Remote Services (SRS) and Secure Connect Gateway (SCG):

Discusses how these tools facilitate remote monitoring and support.

Dell EMC Secure Remote Services

Dell EMC Secure Connect Gateway

Customer Replaceable Units (CRUs):

Lists parts classified as CRUs and guidelines for replacement.

Dell EMC PowerScale Customer Replaceable Units Guide

Knowledge Base Articles:

Article ID 000180123: 'Understanding the AutoCRU Program for Dell PowerScale'

Article ID 000180124: 'Automatic Parts Dispatch with AutoCRU and SRS/SCG'

What is a consideration when reimaging a Dell PowerScale node?

A.

Perform on a node mat is not a member of a cluster.

A.

Perform on a node mat is not a member of a cluster.

Answers
B.

Reimaging does not erase the data and is faster.

B.

Reimaging does not erase the data and is faster.

Answers
C.

Perform on a node that Is a member of a cluster.

C.

Perform on a node that Is a member of a cluster.

Answers
D.

Use the rolling reimage update to retain the current OneFS version.

D.

Use the rolling reimage update to retain the current OneFS version.

Answers
Suggested answer: A

Explanation:

When reimaging a Dell PowerScale node, an important consideration is to perform the reimage on a node that is not a member of a cluster. Reimaging a node that is part of a cluster can lead to data loss and cluster instability. Therefore, the recommended practice is to remove the node from the cluster before initiating the reimage process.

1. Understanding Reimaging:

Reimaging Process:

Reimaging involves reinstalling the OneFS operating system on a node.

It effectively returns the node to a factory-default state.

All data and configurations on the node are erased during the process.

Purpose of Reimaging:

Used to address software corruption, persistent errors, or to prepare a node for redeployment.

2. Importance of Performing Reimage on a Non-Clustered Node:

Data Protection:

Reimaging a node within a cluster can disrupt data protection schemes.

The node's data may not be fully replicated elsewhere, risking data loss.

Cluster Integrity:

Removing the node ensures that the cluster remains stable and avoids potential conflicts.

The cluster's metadata and configuration remain consistent.

Recommended Procedure:

Step 1: Remove the node from the cluster using the appropriate OneFS commands or the WebUI.

Step 2: Confirm that the cluster recognizes the node removal and data has been reprotected.

Step 3: Proceed with reimaging the node.

3. Why Other Options Are Less Suitable:

Option B: Reimaging does not erase the data and is faster.

Incorrect; reimaging erases all data and configurations on the node.

It is not necessarily faster and involves careful steps to ensure data integrity.

Option C: Perform on a node that is a member of a cluster.

Not recommended due to risks of data loss and cluster instability.

Best practices dictate removing the node first.

Option D: Use the rolling reimage update to retain the current OneFS version.

There is no 'rolling reimage update' process.

Rolling upgrades are for updating OneFS versions, not reimaging nodes.

4. Dell PowerScale Best Practices:

Node Removal Before Reimaging:

Always remove the node from the cluster before reimaging.

Ensure the cluster is healthy and data is fully protected.

Backup Critical Data:

Verify that critical data is backed up or replicated.

5. Dell PowerScale

Reference:

Dell EMC PowerScale OneFS Administration Guide:

Provides instructions on managing nodes and reimaging procedures.

Dell EMC PowerScale OneFS Administration Guide

Dell EMC PowerScale OneFS CLI Administration Guide:

Details commands for removing nodes and reimaging.

Dell EMC PowerScale OneFS CLI Guide

Knowledge Base Articles:

Article ID 000180125: 'Best Practices for Reimaging PowerScale Nodes'

Article ID 000180126: 'Procedures for Safely Reimaging a Node'

Which cable is required to connect to the A300 console?

A.

RJ45

A.

RJ45

Answers
B.

DB9-to-DB9

B.

DB9-to-DB9

Answers
C.

VGA

C.

VGA

Answers
D.

USB-to-USB

D.

USB-to-USB

Answers
Suggested answer: A

Explanation:

To connect to the A300 console, a cable with an RJ45 connector is required. The A300 node's console port uses an RJ45 interface for serial communication, allowing administrators to access the console for configuration and troubleshooting.

1. Understanding Console Connections on A300 Nodes:

Console Port Type:

The A300 node features an RJ45 serial console port.

This port provides access to the node's console interface.

Purpose of Console Access:

Allows administrators to perform initial configurations.

Useful for troubleshooting when network access is unavailable.

Provides direct command-line access to the node.

2. Required Cable for Connection:

RJ45 Serial Cable:

A standard RJ45-to-DB9 serial console cable is typically used.

One end has an RJ45 connector (plugs into the node).

The other end may have a DB9 connector (plugs into a computer's serial port) or USB via a serial-to-USB adapter.

Alternative Connection Methods:

If the computer does not have a serial port, a USB-to-serial adapter can be used.

Ensure the correct drivers are installed for the adapter.

3. Why Other Options Are Less Suitable:

Option B: DB9-to-DB9

The A300 uses an RJ45 port, not a DB9 port.

A DB9-to-DB9 cable would not physically connect to the node.

Option C: VGA

VGA is used for video output, not serial console connections.

The A300 does not use VGA for console access.

Option D: USB-to-USB

The A300 does not support console connections via USB-to-USB cables.

USB ports on the node are typically for peripheral devices, not console access.

4. Steps to Connect to the A300 Console:

Step 1: Obtain an RJ45-to-DB9 serial console cable.

Step 2: Connect the RJ45 end to the console port on the A300 node.

Step 3: Connect the DB9 end to the serial port on the computer (or use a USB-to-serial adapter if necessary).

Step 4: Use a terminal emulator (e.g., PuTTY) configured with the appropriate serial settings (usually 115200 baud rate, 8 data bits, no parity, 1 stop bit).

5. Dell PowerScale

Reference:

Dell EMC PowerScale A300 Hardware Guide:

Provides details on hardware components, including console port specifications.

Dell EMC PowerScale A300 Hardware Guide

Dell EMC PowerScale OneFS CLI Administration Guide:

Discusses accessing the CLI via console connections.

Dell EMC PowerScale OneFS CLI Guide

Knowledge Base Articles:

Article ID 000180127: 'Connecting to the Console Port on PowerScale A-Series Nodes'

Article ID 000180128: 'Serial Console Connection Instructions for Dell PowerScale Nodes'

A customer has a Dell EMC PowerScale cluster. The IT manager asks a platform engineer if WORM directories can be overwritten.

A.

Only compliance and secure SmartLock directories need to be reformatted.

A.

Only compliance and secure SmartLock directories need to be reformatted.

Answers
B.

Only enterprise SmartLock directories need to be reformatted.

B.

Only enterprise SmartLock directories need to be reformatted.

Answers
C.

Only enterprise and compliance SmartLock directories need to be reformatted.

C.

Only enterprise and compliance SmartLock directories need to be reformatted.

Answers
D.

Enterprise, compliance, and secure SmartLock directories need to be reformatted.

D.

Enterprise, compliance, and secure SmartLock directories need to be reformatted.

Answers
Suggested answer: D

Explanation:

Dell EMC PowerScale SmartLock is a feature that enables WORM (Write Once Read Many) capabilities on directories, providing data immutability to meet compliance and regulatory requirements. There are three types of SmartLock directories:

Enterprise SmartLock: Offers flexible WORM protection suitable for general business needs.

Compliance SmartLock: Provides stricter WORM enforcement for regulatory compliance.

Secure SmartLock: Enhances Compliance mode with additional security features like role-based access controls.

Once data is written to a WORM directory, it cannot be modified or deleted until the retention period expires. To overwrite or modify data in these directories before the retention period ends, the directories must be reformatted to remove the WORM attributes.

Key Points:

All Types Require Reformatting: To overwrite WORM directories, all types---Enterprise, Compliance, and Secure SmartLock---need to be reformatted.

Reformatting Process: Reformatting removes the WORM protection, allowing changes to be made.

Compliance Implications: Caution must be exercised as reformatting Compliance and Secure directories may have legal and compliance implications.

Dell PowerScale

Reference:

Dell EMC PowerScale OneFS Administration Guide:

Chapter on SmartLock explains the WORM functionality and the immutability of data.

Reformatting SmartLock Directories section details the steps and implications of reformatting.

Best Practices:

Always ensure that reformatting complies with organizational policies and legal requirements.

Document the reformatting process for audit purposes.

A platform engineer has created a cluster of 8 F200 nodes. A requirement is for each power supply on each node to supply power to the respective node equally.

What must the platform engineer do to meet the requirement?

A.

Run the isi config and change the settings in the config subsystem

A.

Run the isi config and change the settings in the config subsystem

Answers
B.

Cable each node power connection to a different PDU in the rack

B.

Cable each node power connection to a different PDU in the rack

Answers
C.

Use the iDRAC settings on each node to disable the hot spare feature

C.

Use the iDRAC settings on each node to disable the hot spare feature

Answers
D.

Run the isi set -n command to change the power supply behavior

D.

Run the isi set -n command to change the power supply behavior

Answers
Suggested answer: C

Explanation:

By default, the Power Supply Hot Spare feature may cause one power supply to run while the other is idle.

Steps to Ensure Equal Power Supply Loading:

Access iDRAC Interface:

Log into the iDRAC for each F200 node.

Disable Hot Spare Feature:

Navigate to Power Management settings.

Disable the Power Supply Hot Spare option.

Result:

Both power supplies will share the load equally.

Dell PowerScale

Reference:

Dell EMC PowerScale F200 Hardware Guide:

Power Supply Configuration:

Instructions on adjusting power supply settings via iDRAC.

Best Practices:

Ensure redundancy by connecting power supplies to separate PDUs.

Monitor power usage to confirm balanced loading.

A platform engineer has added an F200 node to a Dell EMC PowerScale cluster. The cluster now has five F200 nodes.

Before leaving the site, what action must the engineer perform?

A.

Verify the node LNN is set to 1

A.

Verify the node LNN is set to 1

Answers
B.

SmartFail the node and rejoin the cluster

B.

SmartFail the node and rejoin the cluster

Answers
C.

Reboot the node and wait for a green status

C.

Reboot the node and wait for a green status

Answers
D.

Ensure the install base record is updated

D.

Ensure the install base record is updated

Answers
Suggested answer: D

Explanation:

Updating the install base record is crucial for support and warranty purposes.

Reasons:

Accurate Records:

Reflects the current configuration of the cluster.

Support Entitlement:

Ensures timely support services when needed.

Dell PowerScale

Reference:

Dell EMC Support Policies:

Emphasize the importance of maintaining up-to-date asset information.

Best Practices:

Document all changes made to the cluster.

Notify Dell EMC support or use the appropriate channels to update records.

What should the platform engineer pre-check when installing Dell EMC PowerScale Gen 6 nodes in a customer-provided rack?

A.

PDUs are located on opposite sides of the rack

A.

PDUs are located on opposite sides of the rack

Answers
B.

Rack is leveled using the front legs first and the rear legs second

B.

Rack is leveled using the front legs first and the rear legs second

Answers
C.

Rack has full earth ground and is properly bolted to the floor

C.

Rack has full earth ground and is properly bolted to the floor

Answers
D.

Rack has a minimum of two PDUs

D.

Rack has a minimum of two PDUs

Answers
Suggested answer: C

Explanation:

When installing Dell EMC PowerScale Gen 6 nodes in a customer-provided rack, it is crucial for the platform engineer to ensure that the rack meets all safety and installation requirements. One of the most critical pre-checks is verifying that the rack has a full earth ground and is properly bolted to the floor.

Key Points:

Full Earth Ground:

Ensures electrical safety by providing a path for fault currents.

Protects equipment and personnel from electrical hazards.

Reduces the risk of electrical interference affecting the equipment.

Properly Bolted to the Floor:

Provides physical stability to prevent the rack from tipping over.

Essential for seismic compliance in areas prone to earthquakes.

Prevents movement due to vibrations from equipment operation or external factors.

Why This is Important:

Safety Compliance:

Adhering to safety standards is mandatory to prevent accidents.

Electrical grounding is a fundamental requirement for data center equipment installations.

Equipment Protection:

Proper grounding and securing the rack protect sensitive equipment from damage.

Minimizes downtime caused by electrical faults or physical disturbances.

Why Other Options Are Less Critical:

Option A (PDUs on Opposite Sides):

While distributing PDUs can aid in power redundancy and cable management, it is not as critical as grounding and securing the rack.

Option B (Rack Leveling):

Leveling the rack is important for equipment alignment but is a standard step during installation rather than a pre-check.

Option D (Minimum of Two PDUs):

Having multiple PDUs provides redundancy but depends on the power requirements and design of the system.

Dell PowerScale

Reference:

Dell EMC PowerScale Site Preparation and Planning Guide:

Section on Rack Requirements:

Emphasizes that customer-provided racks must be properly grounded and secured.

States that racks should be bolted to the floor to prevent tipping.

Safety Precautions:

Details the importance of electrical grounding for safety and equipment protection.

Best Practices:

Before Installation:

Verify that the rack complies with all local electrical codes and regulations.

Ensure that a qualified electrician has installed the grounding system.

During Installation:

Check that all grounding connections are secure.

Confirm that the rack is level and stable after bolting it to the floor.

After Installation:

Perform an electrical continuity test to verify proper grounding.

Document the installation for future reference and compliance audits.

Total 101 questions